Effects of mineral oil immersion cooling on IT equipment reliability and reliability enhancements to data center operations

JM Shah, R Eiland, A Siddarth… - 2016 15th IEEE …, 2016 - ieeexplore.ieee.org
This paper reviews the changes in physical and chemical properties of information
technology (IT) equipment materials like polyvinyl chloride (PVC), printed circuit board …

Reliability challenges in airside economization and oil immersion cooling

JM Shah - 2016 - mavmatrix.uta.edu
The Datacom facility which comprises rooms or closets used for communication,
computers/servers or electronic equipment requires cooling unit which consumes 31%(23 …

Measurement of the thermal performance of a custom-build single-phase immersion cooled server at various high and low temperatures for prolonged time

PV Bansode, JM Shah, G Gupta… - Journal of …, 2020 - asmedigitalcollection.asme.org
The next radical change in the thermal management of data centers is to shift from
conventional cooling methods like air-cooling to direct liquid cooling to enable high thermal …

Reliability considerations for oil immersion-cooled data centers

JM Shah, R Eiland, P Rajmane… - Journal of …, 2019 - asmedigitalcollection.asme.org
The improved efficiency of mineral oil may offer simplicity in facility design compared to
traditional air cooling and provide a means for cost savings. Despite its improved cooling …

Evaluating the reliability of passive server components for single-phase immersion cooling

JM Shah, K Padmanaban… - Journal of …, 2022 - asmedigitalcollection.asme.org
The adoption of single-phase liquid immersion cooling (Sp-LIC) for Information Technology
equipment provides an excellent cooling platform coupled with significant energy savings …

Computational analysis for thermal optimization of server for single phase immersion cooling

D Gandhi, U Chowdhury… - International …, 2019 - asmedigitalcollection.asme.org
Complete immersion of servers in synthetic dielectric fluids is rapidly becoming a popular
technique to minimize the energy consumed by data centers for cooling purposes. In …

Computational Form Factor Study of a 3rd Generation Open Compute Server for Single-Phase Immersion Cooling

JM Shah, C Bhatt… - International …, 2019 - asmedigitalcollection.asme.org
Networking and computing dependency has been increasing in the modern world, thus,
boosting the growth of data centers in leading business domains like banking, education …

Measurement of the thermal performance of a single-phase immersion cooled server at elevated temperatures for prolonged time

PV Bansode, JM Shah, G Gupta… - International …, 2018 - asmedigitalcollection.asme.org
Fully immersion of servers in electrically nonconductive (dielectric) fluid has recently
become a promising technique for minimizing cooling energy consumption in data centers …

CFD Analysis of Thermal Shadowing and Optimization of Heatsinks in 3rd Generation Open Compute Server for Single-Phase Immersion Cooling

JM Shah, R Dandamudi, C Bhatt… - International …, 2019 - asmedigitalcollection.asme.org
In today's networking world, utilization of servers and data centers has been increasing
significantly. Increasing demand of processing and storage of data causes a corresponding …

[图书][B] Airflow path and flow pattern analysis of sub-micron particulate contaminants in a data center with hot aisle containment system utilizing direct air cooling

S Saini - 2018 - search.proquest.com
The percentage of the energy used by data centers for cooling their equipment has been on
the rise. With it has been the necessity for exploring new and more efficient methods, both …