[HTML][HTML] A review of superconducting fault current limiters compared with other proven technologies

GG Sotelo, G dos Santos, F Sass, BW França… - Superconductivity, 2022 - Elsevier
Several substations in operation were commissioned decades ago. These substations are
overstressed, then their protection equipment cannot provide an effective safety condition to …

On the advance of SFCL: a comprehensive review

MR Barzegar‐Bafrooei, A Akbari Foroud… - IET Generation …, 2019 - Wiley Online Library
This study aims to provide a comprehensive review of various superconducting fault current
limiters (SFCLs) configurations. Regarding the applied technology, the different types of …

Coordination of overcurrent protection relays in networks with superconducting fault current limiters

W Rebizant, K Solak, B Brusilowicz, G Benysek… - International Journal of …, 2018 - Elsevier
The paper concerns coordination of overcurrent (OC) protection relays in power networks
with superconducting fault current limiters (SFCL). At the beginning, information about …

Comparison of inductive and resistive SFCL

J Kozak, M Majka, S Kozak… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
This article presents a comparison of inductive and resistive superconducting fault current
limiter built with the same length of high temperature superconducting (HTS) tape. The …

A new resonant fault current limiter for improved wind turbine transient stability

S Demin, M Sitbon, I Aharon, E Barbi, R Machlev… - Electric Power Systems …, 2023 - Elsevier
This paper proposes a new resonance-type FCL, which is designed specifically for DFIG-
based wind turbines. The proposed topology overcomes the well-documented drawbacks …

Tests and recovery under load simulations of a novel bifilar resistive SFCL having undulated shape configuration

G Dos Santos, A Bitencourt, AT Queiroz… - Superconductor …, 2021 - iopscience.iop.org
Power systems are becoming more interconnected and complex. The distributed generation
expands and spreads across the grids, reducing the distance between the load and the …

Experimental results of a 15 kV, 140 A superconducting fault current limiter

J Kozak, M Majka, S Kozak - IEEE Transactions on Applied …, 2017 - ieeexplore.ieee.org
This paper presents the design and experimental results of a coreless superconducting fault
current limiter (SFCL). The limiter has a rating of 15 kV and 140 A and was tested with a 2.5 …

Dual function ferroresonance and fault current limiter based on DC reactor

H Radmanesh, A Heidary, SH Fathi… - IET Generation …, 2016 - Wiley Online Library
This study presents a novel DC reactor‐based ferroresonance and fault current limiter
(DRFFCL) for stabilising ferroresonance oscillations of potential transformer (PT) in 33 kV …

Design and test of an air coil superconducting fault current limiter demonstrator

O Naeckel, M Noe - IEEE transactions on applied …, 2013 - ieeexplore.ieee.org
This paper discusses the design, set-up and short-circuit testing of an air coil
superconducting fault current limiter demonstrator. The demonstrator was specified for 60 …

[HTML][HTML] Implementation of Series Resonance-Based Fault Current Limiter for Enhanced Transient Stability of Grid-Connected Photovoltaic Farm

S Demin, E Barbie, L Heistrene, J Belikov, E Petlenkov… - Electronics, 2024 - mdpi.com
This paper presents the implementation of an improved resonance-type FCL, designed to
enhance the transient stability of a photovoltaic farm. This FCL overcomes the well-known …