Transition probabilities in Kr II and Kr III spectra

S Djeniže, V Milosavljević, MS Dimitrijević - The European Physical …, 2003 - Springer
On the basis of the relative line intensity ratio (RLIR) method, transition probability values of
the spontaneous emission (Einstein's A values) of 14 transitions in the singly (Kr II) and 7 …

Radiative lifetimes of 5nl states of

K Blagoev, P Bogdanovich, N Dimitrov… - Physical Review A, 1988 - APS
The radiative lifetimes of excited Hg+ 5 d 10 nl states are reported. They are measured by
the multichannel delayed-coincidence method and for some of them Hartree-Fock …

Measurement of the atomic lifetime of Kr ii 5p and Xe ii 6p using the cascade-photon-coincidence technique

RE Mitchell, SD Rosner, TJ Scholl, RA Holt - Physical Review A, 1992 - APS
A high-efficiency cascade-photon-coincidence lifetime-measuring apparatus has been used
to study the 5d 4 F 9/2→ 5p 4 D 7/2 o→ 5s 4 P 5/2 cascade in Kr ii and the 6d 4 F 7/2→ 6p 4 …

Radiative lifetimes of excited Ar II states

KB Blagoev - Journal of Physics B: Atomic and Molecular Physics, 1983 - iopscience.iop.org
Using a delayed-coincidence technique and pulsed electron excitation, the radiative
lifetimes are measured of the Ar II excited states belonging to the electron configurations 4d' …

Radiative lifetimes of some excited states of Hg+ and Hg2+

K Blagoev, N Dimitrov - Physics Letters A, 1986 - Elsevier
A delayed-coincidence method with pulsed electron excitation was used to measure the
radiative lifetimes of some 5d 9 6snl states of Hg+. Radiative lifetimes of five long lived 5d 8 …

Absolute transition rates for transitions from 5p levels in Kr II

K Dzierżęga, U Griesmann, G Nave, Ł Bratasz - Physica Scripta, 2001 - iopscience.iop.org
Branching ratios (BR) were measured for 155 electric dipole transitions from 5p and
5p'levels of singly ionized Kr between 200 nm and 2400 nm. Of these, 83 were measured for …

Radiative lifetimes for some 5p levels of Kr+

JE Lemond, CE Head - Nuclear Instruments and Methods in Physics …, 1987 - Elsevier
Using a Kr+ ion beam from a small positive-ion accelerator, we have measured the radiative
lifetimes of six 5p levels of Kr+ by means of the time-of-flight technique. These levels along …

Linewidth studies on the Kr+ 469.4 nm and 473.9 nm lines excited in a helium-krypton hollow cathode discharge

L Csillag, M Jánossy, K Rózsa - Applied Physics B, 1991 - Springer
Collisional and Doppler linewidths (Δ v C and Δ v D) of the 469.4 nm and 473.9 nm Kr ion
lines were measured in a He-Kr hollow cathode discharge using Fabry-Perot technique. A …

Radiative lifetimes of some excited Xe II states

K Blagoev, N Dimitrov, M Drenska - Journal of Physics B: Atomic …, 1984 - iopscience.iop.org
The radiative lifetimes of some Xe II states belonging to the 6d, 6d'and 7s electron
configurations were determined in the present work. A multichannel delayed-coincidence …

Linewidth studies on the Ar+ 476.5 nm and 480.6 nm lines excited in a helium-agron hollow cathode discharge

L Csillag, M Jánossy - Applied Physics B, 1992 - Springer
The spectral line shapes of the Ar+ 476.5 nm and 480.6 nm lines, excited in a He-Ar hollow
cathode (HC) discharge, were measured using the Fabry-Perot technique. The collisional …