Conceptual seismic design of cable-stayed bridges

GM Calvi, TJ Sullivan, A Villani - Journal of Earthquake …, 2010 - Taylor & Francis
Cable-stayed bridges can be a very effective means of bridging large distances in both
seismic and non-seismic regions. Their design, analysis, and construction can be very …

Smart materials and structures—a finite element approach—an addendum: a bibliography (1997–2002)

J Mackerle - Modelling and Simulation in Materials Science and …, 2003 - iopscience.iop.org
This paper gives a bibliographical review of the finite element methods (FEMs) applied to
the analysis and simulation of smart materials and structures. The bibliography is an …

Hybrid control strategy for seismic protection of a benchmark cable-stayed bridge

KS Park, HJ Jung, IW Lee - Engineering Structures, 2003 - Elsevier
This paper presents a hybrid control strategy for seismic protection of a benchmark cable-
stayed bridge, which is provided as a testbed structure for the development of strategies for …

Sliding mode control of cable-stayed bridge subjected to seismic excitation

SJ Moon, LA Bergman, PG Voulgaris - Journal of Engineering …, 2003 - ascelibrary.org
The working group on bridge control within the ASCE Committee on Structural Control
recently initiated a first-generation benchmark problem addressing the control of a cable …

Hybrid seismic protection of cable‐stayed bridges

HJ Jung, KS Park, BF Spencer Jr… - … engineering & structural …, 2004 - Wiley Online Library
This paper proposes a hybrid control strategy combining passive and semi‐active control
systems for seismic protection of cable‐stayed bridges. The efficacy of this control strategy is …

Hybrid control systems for seismic protection of a phase II benchmark cable‐stayed bridge

KS Park, HJ Jung, BF Spencer Jr… - Journal of Structural …, 2003 - Wiley Online Library
This paper presents hybrid control systems for seismic protection of a phase II benchmark
cable‐stayed bridge. Because multiple control devices are operating, a hybrid control …

Integrated passive-active system for seismic protection of a cable-stayed bridge

KS Park, IW Lee, HJ Jung, JG Park - Journal of earthquake …, 2003 - World Scientific
This paper presents an integrated passive-active (ie hybrid) system for seismic response
control of a cable-stayed bridge. Since multiple control devices are operating, a hybrid …

[PDF][PDF] 旋转柔性梁系统振动频响特性分析及振动抑制

邱志成 - 振动与冲击, 2008 - oss.jishulink.com
航天器挠性附件或柔性机器人等柔性旋转梁系统的模态阻尼小, 由于扰动, 或者在调姿及转动时,
大幅值的振动将持续很长时间, 这将影响系统的稳定性和指向精度, 因此, 必须对振动进行主动 …

Design of an active controller for Quincy Bayview Bridge, Illinois, USA against seismic excitation—Part II: Control implementation

AK Dutta, SK Deb, A Dutta - … Control and Monitoring and of the …, 2008 - Wiley Online Library
In this work two active controllers have been designed against seismic excitation of a real‐
life cable‐stayed bridge, Quincy Bayview Bridge in IL, USA An updated finite element model …

[引用][C] 大跨桥梁结构电磁驱动AMD 系统输入电压的在线控制研究

何敏, 王建国 - 振动与冲击, 2008