ICRP publication 120: radiological protection in cardiology

C Cousins, DL Miller, G Bernardi, MM Rehani… - Annals of the ICRP, 2013 - Elsevier
Cardiac nuclear medicine, cardiac computed tomography (CT), interventional cardiology
procedures, and electrophysiology procedures are increasing in number and account for an …

[HTML][HTML] Editor's choice–minimizing radiation exposure during endovascular procedures: basic knowledge, literature review, and reporting standards

A Hertault, B Maurel, M Midulla, C Bordier… - European Journal of …, 2015 - Elsevier
Context Endovascular procedures, requiring X-ray guidance, are commonly performed in
vascular surgery. X-ray exposure is associated with biological risks for both patients and …

Editor's Choice–European Society for Vascular Surgery (ESVS) 2023 clinical practice guidelines on radiation safety

B Modarai, S Haulon, E Ainsbury, D Böckler… - European journal of …, 2023 - ejves.com
The majority of studies investigating the effectiveness of radiation shields focus on
procedures performed by cardiologists. These studies are, nevertheless, relevant also for …

[PDF][PDF] Quality improvement guidelines for recording patient radiation dose in the medical record for fluoroscopically guided procedures

DL Miller, S Balter, RG Dixon, B Nikolic… - Journal of Vascular …, 2012 - radiation.ncdhhs.gov
The membership of the Society of Interventional Radiology (SIR) Standards of Practice
Committee represents experts in a broad spectrum of interventional procedures from both …

Radiation risk to the fluoroscopy operator and staff

CM Stahl, QC Meisinger, MP Andre… - American Journal of …, 2016 - Am Roentgen Ray Soc
OBJECTIVE. Recent articles discussing cases of brain cancer in interventionalists have
raised concerns regarding the hazards of occupational exposure to ionizing radiation. We …

Skin dose mapping for fluoroscopically guided interventions

PB Johnson, D Borrego, S Balter, K Johnson… - Medical …, 2011 - Wiley Online Library
Purpose: To introduce a new skin dose mapping software system for interventional
fluoroscopy dose assessment and to analyze the benefits and limitations of patient‐phantom …

[HTML][HTML] Review of skin dose calculation software in interventional cardiology

F Malchair, J Dabin, M Deleu, MS Merce, OC Bjelac… - Physica Medica, 2020 - Elsevier
Purpose In interventional cardiology, patients may be exposed to high doses to the skin
resulting in skin burns following single or multiple procedures. Reviewing and analysing …

Reference air kerma and kerma‐area product as estimators of peak skin dose for fluoroscopically guided interventions

D Kwon, MP Little, DL Miller - Medical physics, 2011 - Wiley Online Library
Purpose: To determine more accurate regression formulas for estimating peak skin dose
(PSD) from reference air kerma (RAK) or kerma‐area product (KAP). Methods: After …

Patient dose map indications on interventional X-ray systems and validation with Gafchromic XR-RV3 film

C Bordier, R Klausz, L Desponds - Radiation protection …, 2015 - academic.oup.com
To help avoiding secondary effects of interventional procedures like skin damage, a dose
map method has been developed to provide an indication of the local dose on a surface …

Real-time eye lens dose monitoring during cerebral angiography procedures

MJ Safari, JHD Wong, KAA Kadir, NK Thorpe… - European …, 2016 - Springer
Objectives To develop a real-time dose-monitoring system to measure the patient's eye lens
dose during neuro-interventional procedures. Methods Radiation dose received at left outer …