Protection challenges under bulk penetration of renewable energy resources in power systems: A review

V Telukunta, J Pradhan, A Agrawal… - CSEE journal of …, 2017 - ieeexplore.ieee.org
Among different sources of alternate energy, wind and solar are two prominent and
promising alternatives to meet the future electricity needs for mankind. Generally, these …

Unified power flow controllers in smart power systems: models, methods, and future research

PS Georgilakis, ND Hatziargyriou - IET Smart Grid, 2019 - Wiley Online Library
Power flow control has become increasingly important in recent years in the area of smart
power systems that have to integrate increased shares of variable renewable energy …

A fault detection and classification scheme for unified power flow controller compensated transmission lines connecting wind farms

S Biswas, PK Nayak - IEEE Systems Journal, 2020 - ieeexplore.ieee.org
In recent years, there is an increasing trend of integrating large capacity offshore wind farms
into power grids through UPFC compensated TLs for accommodating large flow of power …

A new differential protection algorithm for transmission lines connected to large-scale wind farms

A Saber, MF Shaaban, HH Zeineldin - … Journal of Electrical Power & Energy …, 2022 - Elsevier
The fluctuated output power of the large-scale wind farms (WF) and their fault transient
characteristics have an adverse effect on the current differential protection systems of the …

Adaptive distance protection scheme for shunt‐FACTS compensated line connecting wind farm

R Dubey, SR Samantaray… - IET Generation …, 2016 - Wiley Online Library
To improve the performance of the conventional distance protection scheme for
compensated lines with high resistance faults, an adaptive distance protection scheme is …

A novel adaptive distance protection scheme for DFIG wind farm collector lines

J Ma, W Zhang, J Liu, JS Thorp - International Journal of Electrical Power & …, 2018 - Elsevier
In view of the sensitivity and selectivity problems in DFIG (doubly-fed induction generator)
wind farm collector line protection, a new adaptive distance protection scheme is proposed …

Adaptive algorithm for transmission line protection in the presence of UPFC

H Mehrjerdi, A Ghorbani - International Journal of Electrical Power & …, 2017 - Elsevier
The presence of flexible ac transmission system (FACTS) controllers in transmission lines
causes mal-operation of distance relays. The series-shunt FACTS devices have larger …

[HTML][HTML] Modern trends in power system protection for distribution grid with high der penetration

R Jain, YN Velaga, K Prabakar, M Baggu… - e-Prime-Advances in …, 2022 - Elsevier
Increasing renewable penetration and grid modernization initiatives are having a significant
impact on the operating and fault characteristics of distribution systems. As a result …

Phase‐space‐based symmetrical fault detection during power swing

R Dubey, SR Samantaray, BK Panigrahi… - IET Generation …, 2016 - Wiley Online Library
This study proposes an effective symmetrical fault detection technique during power swing
in distance relaying using phase‐space (PS) method. This is based on an embedding …

Active power based distance protection scheme in the presence of series compensators

A Ghorbani, SY Ebrahimi… - Protection and control of …, 2017 - ieeexplore.ieee.org
Flexible ac transmission system (FACTS) controllers, especially the series-FACTS
controllers, affect the operation of distance relays and can lead to the relays under/over …