Artificial intelligence biosensors for continuous glucose monitoring

X Jin, A Cai, T Xu, X Zhang - Interdisciplinary Materials, 2023 - Wiley Online Library
Artificial intelligence (AI) algorithms in combination with continuous monitoring technologies
have the potential to revolutionize chronic disease management. The recent innovations in …

Progress of enzymatic and non-enzymatic electrochemical glucose biosensor based on nanomaterial-modified electrode

N Mohamad Nor, NS Ridhuan, K Abdul Razak - Biosensors, 2022 - mdpi.com
This review covers the progress of nanomaterial-modified electrodes for enzymatic and non-
enzymatic glucose biosensors. Fundamental insights into glucose biosensor components …

Electrochemical sensing of analytes in saliva: Challenges, progress, and perspectives

AG Cardoso, H Viltres, GA Ortega, V Phung… - TrAC Trends in …, 2023 - Elsevier
The detection of analytes in human saliva is an important task for real-life sensing device
applications, as well as a challenging issue due to its high viscosity and the presence of …

Advancements in electrochemical glucose sensors

Q Huang, J Chen, Y Zhao, J Huang, H Liu - Talanta, 2025 - Elsevier
The development of electrochemical glucose sensors with high sensitivity, specificity, and
stability, enabling real-time continuous monitoring, has posed a significant challenge …

Cu-based materials: Design strategies (hollow, core-shell, and LDH), sensing performance optimization, and applications in small molecule detection

W Cao, T Guo, J Wang, G Xu, J Jiang, D Liu - Coordination Chemistry …, 2023 - Elsevier
In this review, we present an overview of different methods for preparing Cu-based materials
with a focus on the preparation of hollow structural materials using Kirkendall effect …

Review of oxygen-vacancies nanomaterials for non-enzymatic electrochemical sensors application

L Gurusamy, L Karuppasamy, S Anandan… - Coordination Chemistry …, 2023 - Elsevier
Defect engineering has been extremely effective in enhancing the catalytic performance of
nanomaterials in a variety of applications, including electrochemical sensing …

MOF-derived CuO/CNT for high sensitivity and fast response glucose sensing

Z Shao, Q Gao, S Sun, L Wu, W Feng - Sensors and Actuators B: Chemical, 2024 - Elsevier
The weak conductivity and sluggish electrochemical reaction kinetics lead to low sensitivity
and slow response speed of CuO-based non-enzymatic glucose sensors (NEGSs) …

Hierarchical N-doped porous carbon scaffold Cu/Co-oxide with enhanced electrochemical sensing properties for the detection of glucose in beverages and ascorbic …

W Cao, T Guo, J Wang, Y Ding, B Fan, D Liu - Food Chemistry, 2024 - Elsevier
This research focuses on the development of a highly efficient electrocatalyst, Cu x O/NPC@
Co 3 O 4/NPC-10–7, for detecting glucose and ascorbic acid. In a 0.1 M NaOH solution, the …

Disposable solar microcell array-based addressable photoelectrochemical sensor for high-throughput and multiplexed analysis of salivary metabolites

M Liu, D He, Z Liu, C Hu - Biosensors and Bioelectronics, 2023 - Elsevier
The high-throughput detection of multiple metabolites in saliva by electrochemical sensors is
usually a challenge, which however is essential to the comprehensive evaluation of health …

Non-enzymatic amperometric glucose sensing on CuO/mesoporous TiO 2 modified glassy carbon electrode

M Ali, S Mir, S Ahmed - RSC advances, 2023 - pubs.rsc.org
The present study illustrates the fabrication of a glucose sensing electrode based upon
binary composite of copper oxide and mesoporous titanium dioxide on glassy carbon …