Activation studies for the decommissioning of PET cyclotron bunkers by means of Monte Carlo simulations

S Vichi, A Infantino, F Zagni, G Cicoria… - Radiation Physics and …, 2020 - Elsevier
During the operational life of a PET cyclotron, the concrete walls of the vault are activated by
secondary neutrons. For the dismantling of such accelerator facilities, a considerable …

Activation study of a 15MeV LINAC via Monte Carlo simulations

S Vichi, D Dean, S Ricci, F Zagni, P Berardi… - Radiation Physics and …, 2020 - Elsevier
Medical linear accelerators are increasingly used in radiotherapy. During the operational life
of the accelerator, the different components of the LINAC head become radioactive due to …

Design of a multi-shell portable neutron spectrometry system based on indium foil detectors

A Asuncion-Astronomo, FC Hila, CAM Dingle… - Radiation …, 2020 - Elsevier
A portable neutron spectrometry system was designed based on thermal neutron detectors
embedded in concentric polyethylene spherical shells. The system is flexible and can …

Estimation of neutron production yields from H218O as the 18F-production target bombarded by 18-MeV protons

M Bakhtiari, LM Oranj, NS Jung, A Lee… - Radiation Physics and …, 2020 - Elsevier
Low-energy medical cyclotrons with energy below 20 MeV are widely used to produce short-
lived radionuclides for Positron Emission Tomography (PET). One of the main reactions in …

Activation analysis of RFT-30 cyclotron target assembly

H Lee, S Lee, D Choi, G Jeong, H Seo - Radiation Physics and Chemistry, 2024 - Elsevier
This work evaluated the validity of computer simulation codes by comparing the results of an
inventory calculation for a 89 Zr target assembly with measured data obtained using a high …

[HTML][HTML] Design of proton-beam degrader for high-purity 89Zr production

H Lee, S Lee, D Choi, G Jeong, H Seo - Nuclear Engineering and …, 2024 - Elsevier
This work investigated the most suitable type of degrader (Cu, Al or Nb) and its thickness,
taking into consideration the salient aspects of concrete activation for high-purity 89 Zr …

Characterization of the neutron flux on the surface of a liquid water target intended for 18F production

M Košťál, M Schulc, E Losa, Z Matěj… - Radiation Physics and …, 2021 - Elsevier
Abstract 18 F is an important radioisotope used in nuclear medicine for diagnostic purposes.
It is produced most often via 18 O (p, n) 18 F reaction. During its production, the oxygen …

[PDF][PDF] Experimental, computational, and analytical methods for the characterization of a neutron field for calibration of neutron monitoring instruments in the …

M Grande, FC Hila, A Garalde, CMT Betos… - Philipp. J. Sci …, 2020 - researchgate.net
Despite the many emerging applications of neutron radiation in the Philippines, there is a
gap in the country's capability to calibrate neutron radiation monitoring instruments that are …

Preparation of neutron activated concrete reference material for gamma-ray spectrometry measurement

K Haddad, MS Al-Masri, AH Al Rayyes… - … of Radioanalytical and …, 2024 - Springer
Neutron activated concrete reference material for measurement of residual radioactivity by
gamma-ray spectrometry has been prepared. The main radionuclides were 60Co, 152Eu …

Decommissioning of a Medical Cyclotron Vault: The Case Study of the National Cancer Institute of Milano

A Pola, D Bortot, S Pasquato, D Mazzucconi… - Health …, 2024 - journals.lww.com
In the widespread use of medical cyclotrons for isotope production, radiological and
economic consequences related to the decommissioning of particle accelerators are often …