The progress in development of the Planck-Balance 2 (PB2): a tabletop Kibble balance for the mass calibration of E2 class weights

S Vasilyan, N Rogge, C Rothleitner, S Lin… - tm-Technisches …, 2021 - degruyter.com
In this paper we present the progress in development of a table-top version of the Kibble
balance under the name Planck-Balance 2 (PB2). The PB2 is developed as a collaboration …

Revisiting the limits of photon momentum based optical power measurement method, employing the case of multi-reflected laser beam

S Vasilyan, M López, N Rogge, M Pastuschek… - Metrologia, 2021 - iopscience.iop.org
In this work, we review the viability and precision of the photon-momentum-based optical
power measurement method that employs an amplification effect caused by a multi-reflected …

Deploying the high-power pulsed lasers in precision force metrology–Towards SI traceable and practical force quantization by photon momentum

S Vasilyan, T Fröhlich, N Rogge - tm-Technisches Messen, 2022 - degruyter.com
Abstract Design and operational performance of table-top measurement apparatus is
presented towards direct Planck constant traceable high accuracy and high precision small …

[PDF][PDF] Statische und dynamische Charakterisierung einer Planck-Waage

N Rogge - 2022 - db-thueringen.de
Mein herzlicher Dank gilt dem wissenschaftlichen Betreuer meiner Arbeit Herrn Univ.-Prof.
Dr.-Ing. habil. Thomas Fröhlich ohne dessen Unterstützung nicht die hervorragenden …

Adjustment concept for compensating for stiffness and tilt sensitivity of a novel monolithic electromagnetic force compensation (EMFC) weighing cell

M Pabst, M Darnieder, R Theska… - Journal of Sensors and …, 2022 - jsss.copernicus.org
This paper describes the new adjustment concept of novel planar, monolithic, high-precision
electromagnetic force compensation weighing cells. The concept allows the stiffness and the …

Deploying the high-power pulsed lasers in precision force metrology--SI traceable and practical force quantization by photon momentum

S Vasilyan, T Fröhlich, N Rogge - arXiv preprint arXiv:2205.07042, 2022 - arxiv.org
Design and operational performance of table-top measurement apparatus is presented
towards direct Planck constant traceable high accuracy and high precision small forces and …

Implementation Options of Control Systems for a Cantilever Calibration Device

VA Cherkasova, T Froehlich - 2021 IV International Conference …, 2021 - ieeexplore.ieee.org
The article describes global approaches to control of the cantilever calibration device. The
idea of the device consists in electromagnetic compensation of the influence of cantilever …

Ein neuartiger Ansatz zur Erzeugung eines statischen Drehmoments im Bereich von 1 mN· m bis 1 N· m

T Sasiuk, T Fröhlich, R Theska… - tm-Technisches …, 2021 - degruyter.com
Drehmomentsensoren mit einem kleinen Messbereich bis zu 1 N· m sind Teil verschiedener
Präzisionsgeräte, wie beispielsweise Roboter oder Werkzeuge für medizinische …