Nanosecond pulsed streamer discharges Part I: Generation, source-plasma interaction and energy-efficiency optimization

T Huiskamp - Plasma Sources Science and Technology, 2020 - iopscience.iop.org
Streamer discharges generated by nanosecond high-voltage pulses have gained attraction
for a variety of reasons, but mainly because they are very efficient for a number of plasma …

A high-voltage pulse generator for corona plasma generation

K Yan, EJM Van Heesch, AJM Pemen… - IEEE Transactions …, 2002 - ieeexplore.ieee.org
This paper discusses a high-voltage pulse generator for producing corona plasma. The
generator consists of three resonant charging circuits, a transmission line transformer, and a …

UWB SAR system PULSAR: new generator and antenna developments

P Delmonte, C Dubois, J Andrieu… - … Technology VI and …, 2003 - spiedigitallibrary.org
PULSAR is an Ultra Wide-Band short pulse Radar developed by the CELAR (French
Technical Centre for Armament Electronics) and the IRCOM (Research Institute of …

[PDF][PDF] 级间耦合传输线脉冲变压器

喻斌雄, 苏建仓, 李锐, 赵亮, 张喜波, 王俊杰 - 强激光与粒子束, 2014 - researchgate.net
级间有耦合传输线的脉冲变压器除第一级传输线外所有传输线均绕制在同一磁芯上.
利用电路等效法对该变压器进行了理论分析, 结果表明: 相比采用其他绕线结构的传输线变压器 …

Design of a compact transmission line transformer for high voltage nanosecond pulses

DB Pawelek, P Wouters, AJM Pemen… - … on Dielectrics and …, 2007 - ieeexplore.ieee.org
The area of pulsed-power technology covers a broad range of powers (up to 10 14 W),
voltages (up to 10 6-10 7 V), currents (as high as 10 6 A or higher) and pulse durations …

Transmission line transformers for up to 100 kW pulsed power generation

K Yan, EJM Van Heesch, P Wouters… - … Record of the …, 2002 - ieeexplore.ieee.org
Transmission line transformers (TLTs) are usually used for impedance match. In this paper,
we present a novel circuit topology based on multiple switches and TLTs for both the …

传输线脉冲变压器次级线电感的优化设计

王松松, 杨汉武 - High Power Laser and Particle Beams, 2009 - opticsjournal.net
摘要建立并分析了传输线脉冲变压器的基本电路模型, 采用优化次级线电感参数的方法,
有效地提高了次级线的阻抗, 达到了抑制次级线对输出结果影响的目的. 在此基础上 …

Preliminary study on suppression rate of unbalanced sheath current of coaxial cable using sleeve choke

MG Pan, L Liu, ZB Zhao, Y Xiao… - … on Microwave and …, 2022 - ieeexplore.ieee.org
An approximate analysis method for estimating the spurious radiations from unbalanced
sheath current on a coaxial cable is presented and validated. The coaxial cable is vertically …

A four-stage high-voltage transmission line pulse transformer for transforming a quasi-rectangular pulse

S Wang, H Yang, T Shu - IEEE Transactions on Plasma …, 2013 - ieeexplore.ieee.org
A four-stage high-voltage transmission line pulse transformer with a voltage gain of
approximately 4 is developed for transforming a high-voltage quasi-rectangular pulse with a …

传输线脉冲变压器的频率响应

王松松, 杨汉武, 舒挺 - High Power Laser and Particle Beams, 2009 - opticsjournal.net
摘要采用等效方法简化了多级传输线脉冲变压器(TLT) 电路, 建立了简单的TLT
频率响应分析电路. 在此基础上, 由传输线两端口网络模型推导得到了TLT 的频率响应计算公式 …