The spectroscopy of highly ionised atoms

I Martinson - Reports on Progress in Physics, 1989 - iopscience.iop.org
Spectroscopic investigations of the structure of highly ionised atoms have undergone
significant developments in recent years. The experimental progress is largely due to the …

Demonstration of Soft X-Ray Lasing to Ground State in Li III

DV Korobkin, CH Nam, S Suckewer, A Goltsov - Physical review letters, 1996 - APS
Soft x-ray lasing with a gain length GL≈ 5.5 was demonstrated in hydrogenlike Li III at 13.5
nm (2-1 transition) in a 5 mm long LiF microcapillary using a 50 mJ, 250 fs UV laser beam at …

Resolving power of 35,000 (5 mA) in the extreme ultraviolet employing a grazing incidence spectrometer

MC Hettrick, JH Underwood, PJ Batson, MJ Eckart - Applied optics, 1988 - opg.optica.org
We have experimentally verified the performance predicted for a high-resolution
spectrometer employing a varied line-space plane reflection grating.[1] Figure 1 illustrates …

Measuring the plasma composition in tokamaks with metallic plasma-facing components

M Sertoli, PJ Carvalho, C Giroud, S Menmuir… - Journal of Plasma …, 2019 - cambridge.org
In present and future magnetic confined fusion devices with metallic plasma-facing
components (PFCs) such as JET-ILW and ITER, the calculation of the plasma composition …

Tungsten spectra recorded at the LHD and comparison with calculations

CS Harte, C Suzuki, T Kato, HA Sakaue… - Journal of Physics B …, 2010 - iopscience.iop.org
We have measured extreme ultraviolet (EUV) spectra from highly charged tungsten ions in
low-density and high-temperature plasmas produced in the Large Helical Device at the …

Plasma dynamics in capillary discharge soft X-ray lasers

A Ben-Kish, M Shuker, RA Nemirovsky, A Fisher… - Physical review …, 2001 - APS
The dynamics and stability of collapsing gas columns, generated by a fast capillary
discharge setup, are studied for obtaining soft x-ray amplification in highly ionized ions …

Tracer-encapsulated solid pellet injection system

S Sudo, N Tamura - Review of Scientific Instruments, 2012 - pubs.aip.org
The method of tracer-encapsulated solid pellet (TESPEL) is now flourishing in various fields.
The original purpose to study impurity transport without giving substantial perturbation on …

A review of impurity transport characteristics in the LHD

S Sudo - Plasma Physics and Controlled Fusion, 2016 - iopscience.iop.org
The behavior of impurities in the Large Helical Device (LHD) is reviewed based on the
knowledge acquired since LHD experiments started in 1998. As a result, a consistent …

Flat-field grating spectrometer for high-resolution soft x-ray and extreme ultraviolet measurements on an electron beam ion trap

P Beiersdorfer, EW Magee, E Träbert, H Chen… - Review of scientific …, 2004 - pubs.aip.org
AR= 44.3 m grazing-incidence grating spectrometer has been implemented on the
Livermore electron beam ion traps for high-resolution measurements in the soft x-ray and …

Quasi-Moseley's law for strong narrow bandwidth soft x-ray sources containing higher charge-state ions

H Ohashi, T Higashiguchi, Y Suzuki, G Arai… - Applied Physics …, 2014 - pubs.aip.org
Bright narrow band emission observed in optically thin plasmas of high-Z elements in the
extreme ultraviolet spectral region follows a quasi-Moseley's law. The peak wavelength can …