RC walls in Australia: Seismic design and detailing to AS 1170.4 and AS 3600

SJ Menegon, JL Wilson, NTK Lam… - Australian Journal of …, 2018 - Taylor & Francis
This paper reviews the current seismic design procedures for reinforced concrete buildings
in Australia, with direct reference to the Australian earthquake loading code, AS 1170.4 and …

Experimental investigation of a new precast column-foundation connection under cyclic loading

MT Cogurcu, M Uzun - Journal of Building Engineering, 2022 - Elsevier
In the prefabricated industry, socket connection is generally preferred to be used in column-
foundation connection. In this connection type, the foundations and columns produced in the …

[HTML][HTML] The influence of earthquake characteristics on the seismic performance of reinforced concrete buildings in Australia with varying heights

A Alothman, S Mangalathu, A Al-Mosawe… - Journal of Building …, 2023 - Elsevier
In Australia, most of the existing buildings were designed before the release of the
Australian standard for earthquake actions in 2007. Therefore, many existing buildings in …

Investigation on seismic behavior of RC shear walls with multiple post-construction openings based on experiment and simulation

Y Zhang, G Yuan, Q Shu, M Zhu, L Lu - Journal of Building Engineering, 2022 - Elsevier
The quasi-static tests and finite element simulations of one shear wall without openings and
three shear walls with the same total area but different arrangement of post-construction …

Force-displacement behavior of limited ductile high-strength RC columns under bidirectional earthquake actions

S Raza, SJ Menegon, HH Tsang, JL Wilson - Engineering Structures, 2020 - Elsevier
This paper endeavors to enhance the understanding of the non-linear force-displacement
hysteretic behavior of reinforced concrete (RC) columns subjected to bidirectional …

Framework for seismic vulnerability assessment of reinforced concrete buildings in Australia

SJ Menegon, HH Tsang, E Lumantarna… - Australian Journal of …, 2019 - Taylor & Francis
ABSTRACT The project 'Cost-Effective Mitigation Strategy Development for Building Related
Earthquake Risk'under the Bushfire and Natural Hazards Cooperative Research Centre …

Experimental testing of innovative panel-to-panel connections for precast concrete building cores

SJ Menegon, JL Wilson, NTK Lam, EF Gad - Engineering Structures, 2020 - Elsevier
This paper presents the experimental testing and results of a recent study into panel-to-
panel connections for jointed precast concrete building cores. Panel-to-panel connections …

Experimental testing of reinforced concrete walls in regions of lower seismicity

SJ Menegon, JL Wilson, NTK Lam… - Bulletin of the New …, 2017 - bulletin.nzsee.org.nz
This paper provides an overview and the results of a recent experimental study testing the
lateral cyclic displacement capacity of limited ductile reinforced concrete (RC) walls. The …

[HTML][HTML] Beam-Truss Models to Simulate the Axial-Flexural-Torsional Performance of RC U-Shaped Wall Buildings

R Hoult, AA Correia, JP de Almeida - CivilEng, 2023 - mdpi.com
Reinforced concrete (RC) core walls are commonly used to provide buildings with lateral
and torsional resistance against the actions of wind and earthquakes. In low-to-moderate …

Collapse performance of limited ductile high-strength RC columns under unidirectional cyclic actions

S Raza, SJ Menegon, HH Tsang… - Journal of Structural …, 2020 - ascelibrary.org
The seismic behavior of ductile high-strength RC (HSRC) columns that are constructed in