Semiconductor dosimetry in modern external-beam radiation therapy

AB Rosenfeld, G Biasi, M Petasecca… - Physics in Medicine …, 2020 - iopscience.iop.org
Semiconductor dosimeters are ubiquitous in modern external-beam radiation therapy. They
possess key features. The response, electronically available in real time, is stable and linear …

Fibre-optic dosimetry for MRI-LINACs: a mini-review

L Madden, L Holloway, A Rosenfeld, E Li - Frontiers in Physics, 2022 - frontiersin.org
For the past few decades, fibre-optic dosimeters (FODs) have been a focus of research for
dosimetry with LINACs, owing to a unique set of advantageous qualities: compact dosimeter …

Towards real-time 4D radiation dosimetry on an MRI-Linac

Y De Deene, M Wheatley, B Dong… - Physics in Medicine …, 2020 - iopscience.iop.org
Abstract 4D radiation dosimetry using a highly radiation-sensitive polymer gel dosimeter
with real-time quantitative magnetic resonance imaging (MRI) readout is presented as a …

Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields

OJ Brace, SF Alhujaili, JR Paino… - Journal of Applied …, 2020 - Wiley Online Library
Abstract Purpose The PTW microDiamond has an enhanced spatial resolution when
operated in an edge‐on orientation but is not typically utilized in this orientation due to the …

Dosimetric optimization and commissioning of a high field inline MRI-linac

U Jelen, B Dong, J Begg, N Roberts, B Whelan… - Frontiers in …, 2020 - frontiersin.org
Purpose: Unique characteristics of MRI-linac systems and mutual interactions between their
components pose specific challenges for their commissioning and quality assurance. The …

Characterizing magnetically focused contamination electrons by off‐axis irradiation on an inline MRI‐Linac

E Patterson, BM Oborn, D Cutajar… - Journal of Applied …, 2022 - Wiley Online Library
Purpose The aim of this study is to investigate off‐axis irradiation on the Australian MRI‐
Linac using experiments and Monte Carlo simulations. Simulations are used to verify …

Experimental characterisation of the magnetic field correction factor, for Roos chambers in a parallel MRI-linac

J Begg, U Jelen, P Keall, G Liney… - Physics in Medicine & …, 2022 - iopscience.iop.org
Experimental characterisation of the magnetic field correction factor, for Roos chambers in a
parallel MRI-linac - IOPscience Skip to content IOP Science home Accessibility Help Search …

High-resolution entry and exit surface dosimetry in a 1.5 T MR-linac

E Patterson, P Stokes, D Cutajar, A Rosenfeld… - … Engineering Sciences in …, 2023 - Springer
The magnetic field of a transverse MR-linac alters electron trajectories as the photon beam
transits through materials, causing lower doses at flat entry surfaces and increased doses at …

Electron streaming dose measurements and calculations on a 1.5 T MR‐Linac

E Patterson, M Powers, PE Metcalfe… - Journal of Applied …, 2024 - Wiley Online Library
Purpose To evaluate the accuracy of different dosimeters and the treatment planning system
(TPS) for assessing the skin dose due to the electron streaming effect (ESE) on a 1.5 T …

In-line MRI-LINAC depth dose measurements using an in-house plastic scintillation dosimeter

L Madden, N Roberts, U Jelen, B Dong… - Biomedical Physics …, 2021 - iopscience.iop.org
Plastic scintillation dosimeters (PSDs) have many properties that make them desirable for
relative dosimetry with MRI-LINACs. An in-house PSD, Farmer ionisation chamber and …