Integrated optical devices for lab‐on‐a‐chip biosensing applications

MC Estevez, M Alvarez… - Laser & Photonics …, 2012 - Wiley Online Library
The application of portable, easy‐to‐use and highly sensitive lab‐on‐a‐chip biosensing
devices for real‐time diagnosis could offer significant advantages over current analytical …

[HTML][HTML] Bio-functionalization of microfluidic platforms made of thermoplastic materials: A review

A Shakeri, NA Jarad, S Khan, TF Didar - Analytica Chimica Acta, 2022 - Elsevier
As a result of their favorable physical and chemical characteristics, thermoplastics have
garnered significant interest in the area of microfluidics. The moldable nature of these …

Broad-band Mach-Zehnder interferometers as high performance refractive index sensors: Theory and monolithic implementation

K Misiakos, I Raptis, A Salapatas, E Makarona… - Optics express, 2014 - opg.optica.org
Broad-band Mach-Zehnder interferometry is analytically described and experimentally
demonstrated as an analytical tool capable of high accuracy refractive index measurements …

All-silicon monolithic Mach-Zehnder interferometer as a refractive index and bio-chemical sensor

K Misiakos, I Raptis, E Makarona, A Botsialas… - Optics …, 2014 - opg.optica.org
A complete Mach-Zehnder interferometer monolithically integrated on silicon is presented
and employed as a refractive index and bio-chemical sensor. The device consists of broad …

A fully integrated wireless CMOS microcantilever lab chip for detection of DNA from Hepatitis B virus (HBV)

CW Huang, HT Hsueh, YJ Huang, HH Liao… - Sensors and Actuators B …, 2013 - Elsevier
In this work, a fully integrated DNA detection system-on-a-chip (SoC) was implemented by
0.35 μm commercialized standard CMOS process for label-free and real-time detection of …

Enhanced sensitivity volatile detection with low power integrated micromechanical resonators

DM Karabacak, SH Brongersma, M Crego-Calama - Lab on a Chip, 2010 - pubs.rsc.org
Very high aspect (length/thickness) ratio doubly clamped beams with integrated
piezoelectric transducers are demonstrated for low power sensing of volatiles. The …

Fully integrated monolithic optoelectronic transducer for real-time protein and DNA detection: The NEMOSLAB approach

K Misiakos, PS Petrou, SE Kakabakos… - Biosensors and …, 2010 - Elsevier
The development and testing of a portable bioanalytical device which was capable for real-
time monitoring of binding assays was demonstrated. The device was based on arrays of …

Recent advances in gas phase microcantilever-based sensing

Z Long, L Kou, MJ Sepaniak, X Hou - Reviews in Analytical …, 2013 - degruyter.com
Microcantilever (MC) sensors have become a more attractive technique for gas phase
sensing during recent years. The purpose of this review is to critically summarize the recent …

Low-temperature deposition of high-quality silicon oxynitride films for CMOS-integrated optics

B Rangarajan, AY Kovalgin, K Wörhoff, J Schmitz - Optics letters, 2013 - opg.optica.org
The growth of silicon oxynitride thin films applying remote inductively coupled, plasma-
enhanced chemical vapor deposition is optimized toward high optical quality at a deposition …

Monolithically-integrated Young interferometers for label-free and multiplexed detection of biomolecules

E Savra, A Malainou, A Salapatas… - Silicon …, 2016 - spiedigitallibrary.org
In this work, interferometric silicon chips with monolithically-integrated light-emitting devices
coupled to co-integrated monomodal waveguides shaped as Young interferometers through …