[HTML][HTML] The gas electron multiplier (GEM): Operating principles and applications

F Sauli - Nuclear Instruments and Methods in Physics Research …, 2016 - Elsevier
Introduced by the author in 1997, The Gas Electron Multiplier (GEM) constitutes a powerful
addition to the family of fast radiation detectors; originally developed for particle physics …

[图书][B] Micro-pattern gaseous detectors: Principles of operation and applications

F Sauli - 2020 - books.google.com
As a continuation of the author's earlier work (Gaseous Radiation Detectors: Fundamental
and Applications, Cambridge University Press 2014), this book describes in detail the recent …

Applications of triple GEM detectors beyond particle and nuclear physics

F Murtas - Journal of Instrumentation, 2014 - iopscience.iop.org
Abstract Micro-Pattern Gaseous Detectors (MPGD) have opened the way for the construction
of detectors whose performance surpasses that of the previous generations in terms of …

Triple GEM gas detectors as real time fast neutron beam monitors for spallation neutron sources

F Murtas, G Croci, A Pietropaolo, G Claps… - Journal of …, 2012 - iopscience.iop.org
A fast neutron beam monitor based on a triple Gas Electron Multiplier (GEM) detector was
developed and tested for the ISIS spallation neutron source in UK The test on beam was …

A new 3He-free thermal neutrons detector concept based on the GEM technology

A Pietropaolo, F Murtas, G Claps, L Quintieri… - Nuclear Instruments and …, 2013 - Elsevier
A thermal neutron detector based on the Gas Electron Multiplier technology is presented. It
is configured to let a neutron beam interact with a series of borated glass layers placed in …

Linear accelerator test facility at LNF conceptual design report

P Valente, M Belli, B Bolli, B Buonomo… - arXiv preprint arXiv …, 2016 - arxiv.org
Test beam and irradiation facilities are the key enabling infrastructures for research in high
energy physics (HEP) and astro-particles. In the last 11 years the Beam-Test Facility (BTF) of …

Measurements of γ-ray sensitivity of a GEM based detector using a coincidence technique

G Croci, C Cazzaniga, M Tardocchi… - Journal of …, 2013 - iopscience.iop.org
Abstract Gas Electron Multiplier based detectors have been recently used for neutron
measurement at spallation sources and for fusion relevant applications. The present work is …

nGEM neutron diagnostic concept for high power deuterium beams

G Croci, M Rebai, G Claps, M Cavenago… - Journal of …, 2012 - iopscience.iop.org
The ITER neutral beam test facility under construction in Padova will host two experimental
devices: SPIDER, a 100 kV negative H/D RF source, and MITICA, a full scale, 1 MeV …

GEM-based detectors for thermal and fast neutrons

G Croci, G Claps, C Cazzaniga, L Foggetta… - The European Physical …, 2015 - Springer
Lately the problem of 3 He replacement for neutron detection stimulated an intense activity
research on alternative technologies based on alternative neutron converters. This paper …

GEMINI: A triple-GEM detector read-out mixed-signal ASIC in 180nm CMOS

A Pezzotta, G Corradi, G Croci… - … on Circuits and …, 2015 - ieeexplore.ieee.org
This paper presents GEMINI, an entire read-out System-on-Chip (SoC) to be used with the
Triple Gas-Electron Multiplier (GEM) detector. Designed in CMOS 180 nm technology …