Recent advances in polyaniline composites with metals, metalloids and nonmetals

G Ćirić-Marjanović - Synthetic Metals, 2013 - Elsevier
The recent progress made in the period 2010–2012 in the preparation and application of
polyaniline (PANI) composites with metals, metalloids and nonmetals is reviewed. A …

A Cu2+-Cu/glassy carbon system for glyphosate determination

M del Carmen Aguirre, SE Urreta, CG Gomez - Sensors and Actuators B …, 2019 - Elsevier
Cu° electrocrystallization onto glassy carbon (GC) at potentials between− 0.4 V and− 0.7 V
is consistent with a 3D progressive nucleation mechanism and diffusion-controlled growth …

Voltammetric Quantification of D-penicillamine by Using a Carbon Paste Electrode Modified with WO3 Nanorods and Ionic Liquid as an Efficient Electrochemical …

S Tajik, PM Jahani - Topics in Catalysis, 2024 - Springer
In this work, the electrochemical behavior and sensitive voltammetric determination of D-
penicillamine are described by using a carbon paste electrode modified with WO3 nanorods …

A simple method for determination of D-penicillamine on the carbon paste electrode using cupric ions

A Ghaffarinejad, F Hashemi, Z Nodehi… - Bioelectrochemistry, 2014 - Elsevier
The interaction of d-penicillamine (PA) with copper at the carbon paste electrode (CPE) in
the presence of cupric ions (Cu 2+) was used for the determination of PA at very low …

Construction of a nanocomposite sensor by the modification of a carbon-paste electrode with reduced graphene oxide and a hydroquinone derivative: simultaneous …

A Benvidi, P Dehghan, A Dehghani-Firouzabadi… - Analytical …, 2015 - pubs.rsc.org
The present study reports a sensor for the determination of glutathione using a carbon-paste
electrode modified with reduced graphene oxide (RGO) and 10, 10-dimethyl-7 (3, 4 …

Application of polyaniline for potentiometric recognition of salicylate and its analogues

TV Shishkanova, K Videnská, SG Antonova… - Electrochimica …, 2014 - Elsevier
Presented work proofs usability of polyaniline (PANI) as a receptor for potentiometric
detection of salicylates. The potentiometric selectivity of PANI-coated membranes based on …

Optimization of Graphite-Mineral Oil Ratio With Response Surface Methodology in Glucose Oxidase Based Carbon Paste Electrode Design

E Yağız, G Ozyilmaz, AT Ozyilmaz - Natural and Engineering …, 2022 - dergipark.org.tr
In this study, construction of amperometric glucose biosensor was carried out by
immobilizing of glucose oxidase (GOD) on carbon paste electrode (CPE) which was coated …

Modifiye karbon pasta elektrotlarının yanıt yüzey yöntemi ile optimizasyonu, karakterizasyonu ve biyosensör uygulamalarında kullanımı

E Yağiz - 2015 - acikbilim.yok.gov.tr
Bu çalışmada karbon pasta elektrot (CPE) yüzeyine dönüşümlü voltametri tekniği ile
polianilin (PANI), poli (o-anisidinin)(POA) ve poli (anilin-ko-o-anisidin)(PANI-co-POA) …

[PDF][PDF] SURFACE DEPOSITION OF ZINC OXIDE/VANCOMYCIN FOR ENANTIOSELECTIVE ELECTROCHEMICAL SENSING OF PENICILLAMINE ENANTIOMERS

ALIMT ZHENG - 2018 - psasir.upm.edu.my
The recognition of chiral molecules has been a well-studied subject matter due to their
importance to human mankind. It is well known that enantiomers exhibit differing properties …

اندازه گیری ولتامتری استامینوفن با استفاده از الکترود خمیر کربن اصلاح شده با نانوساختارهای مرتبه‌ای‌ کبالت

امیری, علیمرادی, محسن, نکوئیان - شیمى کاربردى روز, 2012‎ - chemistry.semnan.ac.ir
در این تحقیق، نانوساختارهای مرتبه‌ای کبالت به عنوان اصلاحگر برای تعیین استامینوفن بکار
گرفته شدند. این نانوساختارها با استفاده از یک روش کاهش شیمیایی ساده بدست آمده و سپس توسط …