Assessment of safety of a fully implanted endovascular brain-computer interface for severe paralysis in 4 patients: the stentrode with thought-controlled digital switch …

P Mitchell, SCM Lee, PE Yoo, A Morokoff… - JAMA …, 2023 - jamanetwork.com
Importance Brain-computer interface (BCI) implants have previously required craniotomy to
deliver penetrating or surface electrodes to the brain. Whether a minimally invasive …

Evaluation of a minimally invasive endovascular neural interface for decoding motor activity

IA Forsyth, M Dunston, G Lombardi… - 2019 9th …, 2019 - ieeexplore.ieee.org
Endovascular devices like the Stentrode™ provide a minimally invasive approach to brain-
machine-interfaces that mitigates safety concerns while maintaining good signal quality. Our …

A 10-year journey towards clinical translation of an implantable endovascular BCI A keynote lecture given at the BCI society meeting in Brussels

T Oxley - Journal of Neural Engineering, 2024 - iopscience.iop.org
In the rapidly evolving field of brain-computer interfaces (BCIs), a novel modality for
recording electrical brain signals has quietly emerged over the past decade. The technology …

Distinct neural correlates underlie inhibitory mechanisms of motor inhibition and motor imagery restraint

PE Yoo, TJ Oxley, MA Hagan, S John… - Frontiers in Behavioral …, 2020 - frontiersin.org
There is evidence to suggest that motor execution and motor imagery both involve planning
and execution of the same motor plan, however, in the latter the output is inhibited …

Neurosurgical Considerations for the Brain Computer Interface

JV Rosenfeld, Y Wong, J Szlawski… - Handbook of …, 2023 - Springer
Abstract Brain Computer Interface (BCI) devices are being developed to restore or improve
the function of people suffering with neurological disabilities such as limb paralysis, sensory …

Optimized partial-coverage functional analysis pipeline (OPFAP): a semi-automated pipeline for skull stripping and co-registration of partial-coverage, ultra-high-field …

PE Yoo, JO Cleary, SC Kolbe, RJ Ordidge… - … Resonance Materials in …, 2018 - Springer
Objective Ultra-high-field functional MRI (UHF-fMRI) allows for higher spatiotemporal
resolution imaging. However, higher-resolution imaging entails coverage limitations …

Supplementary Appendix

G Katz - Ann Rheum Dis, 1773 - ard.bmj.com
Supplemental Table 3. The associations of baseline laboratory values with
hypocomplementemia, limited to patients with active, untreated disease. Differences are …