Radionuclide methods and instrumentation for breast cancer detection and diagnosis

S Surti - Seminars in nuclear medicine, 2013 - Elsevier
Breast cancer mammography is a well-acknowledged technique for patient screening due to
its high sensitivity. However, in addition to its low specificity the sensitivity of mammography …

Combined SPECT/CT and PET/CT for breast imaging

P Russo, M Larobina, F Di Lillo, S Del Vecchio… - Nuclear Instruments and …, 2016 - Elsevier
In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly
based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body …

Compton PET: a layered structure PET detector with high performance

P Peng, MS Judenhofer, SR Cherry - Physics in Medicine & …, 2019 - iopscience.iop.org
In most high-resolution PET detector designs, there is an inherent trade-off between spatial
resolution and detector efficiency. We have developed and tested a new geometry for the …

Effects of reflector and crystal surface on the performance of a depth‐encoding PET detector with dual‐ended readout

S Ren, Y Yang, SR Cherry - Medical physics, 2014 - Wiley Online Library
Purpose: Depth encoding detectors are required to improve the spatial resolution and
spatial resolution uniformity of small animal positron emission tomography (PET) scanners …

Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit

M Li, S Abbaszadeh - Physics in Medicine & Biology, 2019 - iopscience.iop.org
Abstract Depth-of-interaction (DOI) capability is important for achieving high spatial
resolution and sensitivity in dedicated organ and small animal positron emission …

Depth‐of‐interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual‐ended signal readout

M Seo, H Park, S Lee, GB Ko, JS Lee - Medical Physics, 2023 - Wiley Online Library
Background Small‐animal positron emission tomography (PET) systems are widely used in
molecular imaging research and drug development. There is also growing interest in organ …

Development and initial characterization of a high-resolution PET detector module with DOI

M Li, Y Wang, S Abbaszadeh - Biomedical physics & engineering …, 2020 - iopscience.iop.org
Organ-dedicated PET scanners are becoming more prevalent because of their advantages
in higher sensitivity, improved image quality, and lower cost. Detectors utilized in these …

Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics

Y Shao, X Sun, KA Lan, C Bircher… - Physics in Medicine & …, 2014 - iopscience.iop.org
In this study, we developed a prototype animal PET by applying several novel technologies
to use solid-state photomultiplier (SSPM) arrays to measure the depth of interaction (DOI) …

A crosshair light sharing PET detector with DOI and TOF capabilities using four-to-one coupling and single-ended readout

E Yoshida, F Obata, K Kamada… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
To improve positron emission tomography (PET) image quality, depth-of-interaction (DOI)
information and time-of-flight (TOF) information are key technologies. In this work, we …

Polaroid-PET: a PET scanner with detectors fitted with Polaroid for filtering unpolarized optical photons—a Monte Carlo simulation study

A Sanaat, A Ashrafi-Belgabad… - Physics in Medicine & …, 2020 - iopscience.iop.org
We propose and evaluate the performance of an improved preclinical positron emission
tomography (PET) scanner design, referred to as Polaroid-PET, consisting of a detector …