[HTML][HTML] Autoinjector–A smart device for emergency cum personal therapy

A Roy, RV Geetha, A Magesh, R Vijayaraghavan… - Saudi Pharmaceutical …, 2021 - Elsevier
Autoinjectors are self-injectable devices; they are important class of medical devices which
can deliver drugs through subcutaneous or intramuscular route. They enclose prefilled …

The adherence and outcomes benefits of using a connected, reusable auto-injector for self-injecting biologics: a narrative review

A Antalfy, K Berman, C Everitt, R Alten, M Latymer… - Advances in …, 2023 - Springer
Many biologics are now self-administered by patients at home. A variety of self-injection
devices are available, including vials and syringes, prefilled syringes, and spring-driven …

Payer perspectives on intravenous versus subcutaneous administration of drugs

RS Epstein - ClinicoEconomics and Outcomes Research, 2021 - Taylor & Francis
Abstract The coronavirus disease 2019 (COVID-19) pandemic has brought increased
attention to vulnerable populations such as older or immunocompromised patients and …

Objective medication adherence and persistence in people with multiple sclerosis: a systematic review, meta-analysis, and meta-regression

J Mardan, MA Hussain, M Allan, LB Grech - Journal of Managed Care & …, 2021 - jmcp.org
BACKGROUND: Medication adherence is critical for the realization of pharmacotherapy
benefits and reduced healthcare expenditure. Studies have shown up to 60% of people with …

Connected drug delivery devices to complement drug treatments: potential to facilitate disease management in home setting

B Bittner, C Schmit Chiesi, S Kharawala… - Medical Devices …, 2019 - Taylor & Francis
Connected drug delivery devices are increasingly being developed to support patient
supervision and counseling in home setting. Features may include dosing reminders …

Design Development of the SMARTCLIC®/CLICWISE® Injection Device for Self-Administered Subcutaneous Therapies: Findings from Usability and Human Factor …

K Berman, S Moss, B Holden-Theunissen, N Satou… - Advances in …, 2023 - Springer
Introduction An easy-to-use, multiuse, single-patient, electromechanical autoinjector, the
SMARTCLIC®/CLICWISE® injection device, was recently developed to improve the self …

Using patient feedback to optimize the design of a certolizumab pegol electromechanical self-injection device: insights from human factors studies

B Domańska, O Stumpp, S Poon, S Oray, I Mountian… - Advances in …, 2018 - Springer
Introduction We incorporated patient feedback from human factors studies (HFS) in the
patient-centric design and validation of ava®, an electromechanical device (e-Device) for …

Adherence to treatment in children with growth hormone deficiency, small for gestational age and Turner syndrome in Mexico: results of the Easypod™ connect …

A Blanco-López, C Antillón-Ferreira… - Journal of …, 2020 - Springer
Background Assessing adherence to growth hormone (GH) is challenging. The Easypod™
connect device delivers pre-set doses of recombinant human GH (r-hGH) and stores a …

Evolution of the RebiSmart® Electromechanical Autoinjector to Improve Usability in Support of Adherence to Subcutaneous Interferon Beta-1a Therapy for People …

YT Lin, T Will, C Wickham, P Boeree… - Patient preference …, 2023 - Taylor & Francis
Background The RebiSmart® electromechanical autoinjector supports people living with
relapsing multiple sclerosis (MS) with their adherence to treatment with subcutaneous …

Subjective patient-reported versus objective adherence to subcutaneous interferon β-1a in multiple sclerosis using RebiSmart®: the CORE study

C Zecca, G Disanto, S Mühl, C Gobbi - BMC neurology, 2017 - Springer
Background Patient adherence to treatment is key to preventing the worsening of
neurological disability in multiple sclerosis (MS). The RebiSmart® autoinjector facilitates self …