A robust single ended disturbance detection scheme for superconducting fault current limiter integrated UPFC compensated line

A Panday, MT Ahmad, S Biswal, RD Patidar… - Electric Power Systems …, 2023 - Elsevier
The occurrence of short circuit events in a high voltage or extra high voltage transmission
system may result in a fault current with high magnitudes. Additionally, the inclusion of …

Taylor series based protection starting element for STATCOM compensated transmission line

P Mundra, A Arya, SK Gawre, S Biswal… - Electric Power Systems …, 2022 - Elsevier
In the presence of nonlinear response created by power electronics-based compensators,
reliable fault detection and classification by distance protection relays is a major concern …

Wavelet synchro-squeezing transform and dynamic threshold supported symmetrical power swing technique for modern transmission network

M Biswal, KR Andanapalli, P Ray - Chinese Journal of …, 2024 - ieeexplore.ieee.org
Distance relays are prone to symmetrical power swing phenomenon. To mitigate this issue,
a dynamic threshold-supported algorithm is proposed. A single logic is not supposed to be …

Integrated wide-area backup protection algorithm during stressed power system condition in presence of wind farm

S Biswal, SD Swain, RD Patidar, AK Bhoi… - Arabian Journal for …, 2021 - Springer
Stressed power system conditions such as power swing, voltage instability and load
encroachment may influence the secure operation of conventional backup protection at their …

Kullback‐Leibler divergence based differential protection scheme for shunt compensated transmission line

S Biswal, M Tajdinian, AR Adly… - IET Generation …, 2021 - Wiley Online Library
Conventional transmission line protection algorithms may experience delay or even mal‐
operation in presence of shunt compensation due to various non‐fault transient …

Intrinsic time decomposition based differential protection with adaptive threshold for UPFC compensated transmission line

A Panday, RD Patidar, S Biswal - International Journal of Emerging …, 2022 - degruyter.com
In the presence of nonlinear response created by power electronics-based compensators,
reliable fault detection and classification by distance protection relays is a major concern …

Rapid Generation of DFIG Farm Equivalent Model Evaluation Scenario Based on Deep Belief Network

H Jiang, L Xu, X Cui, J Wu, J Feng… - 2023 7th International …, 2023 - ieeexplore.ieee.org
The protection link within the wind farm is the key link that affects the transient characteristics
of the wind farm, and also has the greatest impact on the complexity of scene construction …

[PDF][PDF] Analise de transitorios de falta em linha de transmissao considerando conexao de parque eolico interfaceado por converosores

JS Costa, LA Gama, RT Toledo, GB Santos… - 12Âo SEMINAR ON …, 2019 - conprove.com
Neste trabalho, apresenta-se uma análise de transitórios de falta em uma linha de
transmissão (LT) de 500 kV/60 Hz, a qual conecta um parque eólico interfaceado por …

Avaliação de relés microprocessados reais aplicados na proteção de linhas de transmissão de interconexão de parques eólicos

JS Costa - 2022 - icts.unb.br
Neste trabalho é avaliado o desempenho de funções de proteção de linhas de transmissão
no domínio do tempo, TD21 e TW87, e fasorial, PH21 e PH87, disponíveis em relés reais …