Local pulse wave velocity: theory, methods, advancements, and clinical applications

PM Nabeel, VR Kiran, J Joseph… - IEEE Reviews in …, 2019 - ieeexplore.ieee.org
Local pulse wave velocity (PWV) is evolving as one of the important determinants of arterial
hemodynamics, localized vessel stiffening associated with several pathologies, and a host …

Wearable continuous blood pressure monitoring devices based on pulse wave transit time and pulse arrival time: A review

ZB Zhou, TR Cui, D Li, JM Jian, Z Li, SR Ji, X Li, JD Xu… - Materials, 2023 - mdpi.com
Continuous blood pressure (BP) monitoring is of great significance for the real-time
monitoring and early prevention of cardiovascular diseases. Recently, wearable BP …

Ballistocardiogram as proximal timing reference for pulse transit time measurement: Potential for cuffless blood pressure monitoring

CS Kim, AM Carek, R Mukkamala… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
Goal: We tested the hypothesis that the ballistocardiogram (BCG) waveform could yield a
viable proximal timing reference for measuring pulse transit time (PTT). Methods: From 15 …

A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time

D Buxi, JM Redoute, MR Yuce - Physiological measurement, 2015 - iopscience.iop.org
Blood pressure monitoring based on pulse transit or arrival time has been the focus of much
research in order to design ambulatory blood pressure monitors. The accuracy of these …

Continuous PPG-based blood pressure monitoring using multi-linear regression

S Haddad, A Boukhayma… - IEEE journal of …, 2021 - ieeexplore.ieee.org
In this work, we present a photoplethy smography-based blood pressure monitoring
algorithm (PPG-BPM) that solely requires a photoplethysmography (PPG) signal. The …

Noninvasive and nonocclusive blood pressure estimation via a chest sensor

J Sola, M Proença, D Ferrario… - IEEE Transactions …, 2013 - ieeexplore.ieee.org
The clinical demand for a device to monitor blood pressure (BP) in ambulatory scenarios
with minimal use of inflation cuffs is increasing. Based on the so-called pulse wave velocity …

Blood pressure estimation using pulse transit time from bioimpedance and continuous wave radar

D Buxi, JM Redouté, MR Yuce - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
Objective: We have developed and tested a new architecture for pulse transit time (PTT)
estimation at the central arteries using electrical bioimpedance, electrocardiogram, and …

Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique

PM Nabeel, J Jayaraj… - Physiological …, 2017 - iopscience.iop.org
Objective: A novel photoplethysmograph probe employing dual photodiodes excited using a
single infrared light source was developed for local pulse wave velocity (PWV) …

Pulse wave velocity measurement with multiplexed fiber optic Fabry–Pérot interferometric sensors

NA Ushakov, AA Markvart… - IEEE Sensors …, 2020 - ieeexplore.ieee.org
The paper presents an approach to noninvasively measure pulse wave delay and velocity
by means of two multiplexed fiber-optic Fabry-Perot interferometric sensors interrogated by …

Arterial blood pressure estimation from local pulse wave velocity using dual-element photoplethysmograph probe

PM Nabeel, S Karthik, J Joseph… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
An arterial compliance, dual-element photoplethysmograph probe for local pulse wave
velocity (PWV) measurement was developed. Initially, the experimental validation study was …