Tolerance limits and methodologies for IMRT measurement‐based verification QA: Recommendations of AAPM Task Group No. 218

M Miften, A Olch, D Mihailidis, J Moran… - Medical …, 2018 - Wiley Online Library
Purpose Patient‐specific IMRT QA measurements are important components of processes
designed to identify discrepancies between calculated and delivered radiation doses …

Semiconductor dosimetry in modern external-beam radiation therapy

AB Rosenfeld, G Biasi, M Petasecca… - Physics in Medicine …, 2020 - iopscience.iop.org
Semiconductor dosimeters are ubiquitous in modern external-beam radiation therapy. They
possess key features. The response, electronically available in real time, is stable and linear …

AAPM Task Group 198 Report: An implementation guide for TG 142 quality assurance of medical accelerators

J Hanley, S Dresser, W Simon, R Flynn… - Medical …, 2021 - Wiley Online Library
The charges on this task group (TG) were as follows:(a) provide specific procedural
guidelines for performing the tests recommended in TG 142;(b) provide estimate of the …

A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems

M Hussein, P Rowshanfarzad, MA Ebert… - Radiotherapy and …, 2013 - Elsevier
Purpose To investigate the variability of the global gamma index (γ) analysis in various
commercial IMRT/VMAT QA systems and to assess the impact of measurement with low …

On the sensitivity of common gamma‐index evaluation methods to MLC misalignments in Rapidarc quality assurance

G Heilemann, B Poppe, W Laub - Medical physics, 2013 - Wiley Online Library
Purpose: In this study the effects of small systematic MLC misalignments and gravitational
errors on the quality of Rapidarc treatment plan delivery are investigated with respect to …

Multi‐institution validation of a new high spatial resolution diode array for SRS and SBRT plan pretreatment quality assurance

MS Rose, L Tirpak, K Van Casteren, J Zack… - Medical …, 2020 - Wiley Online Library
Purpose The SRS MapCHECK®, a recently developed patient‐specific quality assurance
(PSQA) tool for end‐to‐end testing of stereotactic radiosurgery (SRS) and stereotactic body …

Evaluation of the ArcCHECK QA system for IMRT and VMAT verification

G Li, Y Zhang, X Jiang, S Bai, G Peng, K Wu, Q Jiang - Physica medica, 2013 - Elsevier
The purposes of this study were to perform tests for the ArcCHECK QA system, and to
evaluate the suitability of this system for IMRT and VMAT verification. The device was tested …

True 3D chemical dosimetry (gels, plastics): Development and clinical role

LJ Schreiner - Journal of Physics: Conference Series, 2015 - iopscience.iop.org
Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the
1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic …

Patient QA systems for rotational radiation therapy: a comparative experimental study with intentional errors

A Fredh, JB Scherman, LS Fog… - Medical …, 2013 - Wiley Online Library
Purpose: The purpose of the present study was to investigate the ability of commercial
patient quality assurance (QA) systems to detect linear accelerator‐related errors. Methods …

Correlation of phantom‐based and log file patient‐specific QA with complexity scores for VMAT

CE Agnew, DM Irvine… - Journal of applied clinical …, 2014 - Wiley Online Library
The motivation for this study was to reduce physics workload relating to patient‐specific
quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre …