[HTML][HTML] Protein immobilization techniques for microfluidic assays

D Kim, AE Herr - Biomicrofluidics, 2013 - pubs.aip.org
Microfluidic systems have shown unequivocal performance improvements over conventional
bench-top assays across a range of performance metrics. For example, specific advances …

Current development in microfluidic immunosensing chip

TG Henares, F Mizutani, H Hisamoto - Analytica chimica acta, 2008 - Elsevier
This review accounts for the current development in microfluidic immunosensing chips. The
basic knowledge of immunoassay in relation to its microfluidic material substrate, fluid …

Modified paramagnetic beads in a microfluidic system for the determination of ethinylestradiol (EE2) in river water samples

NA Martínez, RJ Schneider, GA Messina… - Biosensors and …, 2010 - Elsevier
In this work, we have developed and characterized a novel microfluidic immunoassay
methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water …

Microfluidic chip made of COP (cyclo-olefin polymer) and comparion to PMMA (polymethylmethacrylate) microfluidic chip

L Yi, W Xiaodong, Y Fan - Journal of Materials Processing Technology, 2008 - Elsevier
Hot embossing method was studied for the fabrication of microfluidic microchannels on COP
(cyclo-olefin polymer) chip. The ending temperature of heating stage, ie embossing …

Lab-on-a-chip immunoassay for multiple antibodies using microsphere light scattering and quantum dot emission

LJ Lucas, J Chesler, JY Yoon - 2007 ASAE Annual Meeting, 2007 - elibrary.asabe.org
Detection of multiple biomarkers has recently received great interest from the biosensors
community. These diagnostic methods must be rapid, specific, sensitive, and cost-effective …

A highly hydrophilic cation exchange nonwoven with a further modifiable epoxy group prepared by radiation-induced graft polymerization

X Pan, J Zu - Polymer chemistry, 2021 - pubs.rsc.org
Novel cation exchange nonwoven PP-g-SSS/GMA containing epoxy and sulfonic groups
was successfully prepared via radiation-induced simultaneous grafting polymerization by …

Microfluidic immunosensor with micromagnetic beads coupled to carbon-based screen-printed electrodes (SPCEs) for determination of Botrytis cinerea in tissue of …

MA Fernandez-Baldo, GA Messina… - Journal of agricultural …, 2010 - ACS Publications
A wide range of plant species, including economically important crops such as vegetables,
ornamentals, bulbs, and fundamentally fruits, can be affected by gray mold caused by the …

A ready-to-use, versatile, multiplex-able three-dimensional scaffold-based immunoassay chip for high throughput hepatotoxicity evaluation

X Yan, J Wang, L Zhu, JJ Lowrey, Y Zhang, W Hou… - Lab on a Chip, 2015 - pubs.rsc.org
Hydrogel as three-dimensional (3D) substrate has been employed in miniaturized high
throughput protein detection platforms to increase the number of effective antibodies and …

Miniaturized tools and devices for bioanalytical applications: an overview

M Chudy, I Grabowska, P Ciosek… - Analytical and …, 2009 - Springer
This article presents an overview of various miniaturized devices and technologies
developed by our group. Innovative, fast and cheap procedures for the fabrication of …

Microfluidic-enzymatic biosensor with immobilized tyrosinase for electrochemical detection of pipemidic acid in pharmaceutical samples

FA Bertolino, IE De Vito, GA Messina… - Journal of …, 2011 - Elsevier
The present article describes the development of a microfluidic-enzymatic sensor with
electrochemical detection for the quantification of pipemidic acid (PA), which is a synthetic …