Aortic root enlargement is safe and reduces the incidence of patient-prosthesis mismatch: a meta-analysis of early and late outcomes

W Yu, DY Tam, RV Rocha, A Makhdoum… - Canadian Journal of …, 2019 - Elsevier
Background Aortic root enlargement (ARE) may be an important adjunct to aortic valve
replacement (AVR) to prevent patient-prosthesis mismatch and facilitate future valve-in …

Balloon-expandable versus self-expanding transcatheter aortic valve replacement for bioprosthetic dysfunction: A systematic review and meta-analysis

HA Lee, AH Chou, VCC Wu, DY Chen, HF Lee… - PLoS …, 2020 - journals.plos.org
Background Transcatheter aortic valve-in-valve (VIV) procedure is a safe alternative to
conventional reoperation for bioprosthetic dysfunction. Balloon-expandable valve (BEV) and …

Valve‐in‐valve transcatheter aortic valve replacement versus redo surgical valve replacement for degenerated bioprosthetic aortic valve: An updated meta‐analysis …

A Thandra, W Abusnina, A Jhand… - Catheterization and …, 2021 - Wiley Online Library
Background Redo surgical aortic valve replacement (redo SAVR) and valve‐in‐valve
transcatheter aortic valve replacement (ViV TAVR) are the two treatment strategies available …

Is bioprosthetic valve fracture beneficial for patients with larger surgical valves undergoing valve in valve TAVR?

AK Chhatriwalla, JT Saxon, DJ Cohen… - Current Cardiology …, 2018 - Springer
Abstract Purpose of Review This review aims to summarize data regarding bioprosthetic
valve fracture (BVF), a novel technique that involves fracturing the surgical valve sewing ring …

Peri-procedural outcome according to VARC-3 criteria and hemodynamic mid-term follow-up after Valve-in-valve transcatheter aortic valve replacement for failed …

K Takagi, N Kawamoto, Y Irie, T Kakuta… - Cardiovascular …, 2024 - Springer
Despite the widespread adoption of valve-in-valve transcatheter aortic valve replacement
(VIV-TAVR) for patients with failed aortic bioprosthesis, the effectiveness of this treatment for …

Transcatheter aortic valve‐in‐valve implantation for failed surgical bioprosthetic valves. A minimalist approach without contrast aortography or echocardiographic …

A Attinger‐Toller, NM Htun, D Murdoch… - Catheterization and …, 2020 - Wiley Online Library
Objectives To demonstrate safety, feasibility and short‐term clinical outcomes after
transcatheter aortic valve‐in‐valve (ViV) implantation under local anesthesia without …

Influence of Mitroflow bioprosthesis structural valve deterioration on cardiac morbidity

F Waziri, Z Karunanithi, BB Løgstrup, V Hjortdal… - Journal of …, 2019 - Springer
Background This study investigated the extent and nature of cardiac morbidity and cause of
mortality in patients with Mitroflow structural valve deterioration (SVD). Methods A …

Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test

AL Mota, DF Gaia, JHP Fonseca - Brazilian Journal of Cardiovascular …, 2022 - SciELO Brasil
Introduction: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown
low complication rates and presents as an option in the treatment of patients at high risk for …

Intentional bioprosthetic tricuspid valve fracture to facilitate transcatheter valve‐in‐valve deployment

B Karahalios, JP Breinholt, SH Little… - Catheterization and …, 2021 - Wiley Online Library
While transcatheter valve‐in‐valve (ViV) implantation may reduce the number of lifetime
surgical reinterventions in some patients with congenital heart disease, in other patients the …

[HTML][HTML] High Residual Gradient Following a Self-Expandable Transcatheter Aortic Valve-in-Valve Implantation—Risk Factor Analysis, Outcomes, and Survival

T Stankowski, SS Aboul-Hassan, P Stepinski… - Brazilian Journal of …, 2021 - SciELO Brasil
Introduction: Transcatheter aortic valve-in-valve implantation (TAVI-ViV) can be associated
with unfavorable hemodynamic outcomes. This study aimed to estimate the prevalence …