[HTML][HTML] Arterial blood gas

D Castro, S Patil, M Zubair, M Keenaghan - StatPearls, 2024 - statpearls.com
Blood gas analysis is a commonly used diagnostic tool to evaluate the partial pressures of
gas in blood and acid-base content. Understanding and using blood gas analysis enables …

Transfontanelle photoacoustic imaging for in-vivo cerebral oxygenation measurement

R Manwar, LS McGuire, MT Islam, A Shoo… - Scientific Reports, 2022 - nature.com
The capability of photoacoustic (PA) imaging to measure oxygen saturation through a
fontanelle has been demonstrated in large animals in-vivo. We called this method …

Laboratory testing of extravascular body fluids: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Part I …

L Milevoj Kopcinovic, J Culej, A Jokic, M Bozovic… - Biochemia …, 2020 - hrcak.srce.hr
Review Page 1 https://doi.org/10.11613/BM.2020.010502 Biochem Med (Zagreb) 2020;30(1):010502
1 Abstract Extravascular body fluids (EBF) analysis can provide useful information in the …

Preliminary research on the effect of hyperbaric oxygen therapy in patients with post-COVID-19 syndrome

D Kitala, W Łabuś, J Kozielski, P Strzelec… - Journal of Clinical …, 2022 - mdpi.com
Negative consequences and medical complications of COVID-19 can persist for up to
several months after initial recovery. These consequences can include stroke, diabetes …

Failure Mode and Effects Analysis (FMEA) at the preanalytical phase for POCT blood gas analysis: proposal for a shared proactive risk analysis model

V Van Hoof, S Bench, AB Soto, PP Luppa… - Clinical Chemistry and …, 2022 - degruyter.com
Objectives Proposal of a risk analysis model to diminish negative impact on patient care by
preanalytical errors in blood gas analysis (BGA). Methods Here we designed a Failure Mode …

Pitfalls in the diagnosis and management of acid–base disorders in humans: a laboratory medicine perspective

H Carlton, KE Shipman - Journal of Clinical Pathology, 2024 - jcp.bmj.com
Diagnostic errors affect patient management, and as blood gas analysis is mainly performed
without the laboratory, users must be aware of the potential pitfalls. The aim was to provide a …

Transcutaneous Flexible Sensor for In Vivo Photonic Detection of pH and Lactate

D Nguyen, MM Lawrence, H Berg, MA Lyons… - ACS …, 2022 - ACS Publications
Clinical research shows that frequent measurements of both pH and lactate can help guide
therapy and improve patient outcome. However, current methods of sampling blood pH and …

[HTML][HTML] Detection of preanalytical errors in arterial blood gas analysis

S Çuhadar, H Özkanay-Yörük, M Köseoğlu… - Biochemia …, 2022 - hrcak.srce.hr
Detection of preanalytical errors in arterial blood gas analysis Skoči na glavni sadržaj english
Prijava i registracija Prijava Promjena načina autentikacije Registracija srce logo Navigation 1 …

[HTML][HTML] Stability of pH, blood gas partial pressure, hemoglobin oxygen saturation fraction, and lactate concentration

A Arbiol-Roca, CE Imperiali… - Annals of laboratory …, 2020 - synapse.koreamed.org
Background The storage temperature and time of blood gas samples collected in syringes
constitute preanalytical variables that could affect blood gas or lactate concentration …

The P50 value detected by the oxygenation-dissociation analyser and blood gas analyser

Z Chu, Y Wang, G You, Q Wang, N Ma, B Li… - Artificial Cells …, 2020 - Taylor & Francis
Oxygen tension at 50% haemoglobin saturation (P50), which reflects the degree of
peripheral oxygen offloading and tissue oxygenation, plays an important role in the …