Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data

A Barre, S Armand - Computer methods and programs in biomedicine, 2014 - Elsevier
C3D file format is widely used in the biomechanical field by companies and laboratories to
store motion capture systems data. However, few software packages can visualize and …

Wear estimation at the contact surfaces of oval shaped hip implants using finite element analysis

N Shaikh, S Shenoy B, S Bhat N, S Shetty… - Cogent …, 2023 - Taylor & Francis
The hip joint is one of the most essential joints for transmitting weights to the lower abdomen
during day-to-day activities. Loosening of hip implants is mostly caused by wear. The wear …

[PDF][PDF] Effect of coating materials on the fatigue behavior of hip implants: a three-dimensional finite element analysis

A Darwich, H Nazha, M Daoud - Journal of Applied and …, 2020 - jacm.scu.ac.ir
This study aims to validate, using finite element analysis (FEA), the design concept by
comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) …

A structural numerical model for the optimization of double pelvic osteotomy in the early treatment of canine hip dysplasia

EM Zanetti, M Terzini, L Mossa… - Veterinary and …, 2017 - thieme-connect.com
Background: Double pelvic osteotomy (DPO) planning is usually performed by hip palpation,
and on radiographic images which give a poor representation of the complex three …

A novel approach for dynamic testing of total hip dislocation under physiological conditions

S Herrmann, D Kluess, M Kaehler, R Grawe… - PLoS …, 2015 - journals.plos.org
Constant high rates of dislocation-related complications of total hip replacements (THRs)
show that contributing factors like implant position and design, soft tissue condition and …

Development of a hardware-in-loop attitude control simulator for a CubeSat satellite

W Tapsawat, T Sangpet… - IOP Conference Series …, 2018 - iopscience.iop.org
Attitude control is an important part in satellite on-orbit operation. It greatly affects the
performance of satellites. Testing of an attitude determination and control subsystem (ADCS) …

HiL simulation for testing joint stability after total knee arthroplasty

S Herrmann, C Woernle, M Kaehler… - Multibody System …, 2012 - Springer
Instability of total knee replacements (TKRs) remains one of the most prevalent
complications after total knee arthroplasty. Especially the actual event of instability involving …

Dynamical analysis of dislocation‐associated factors in total hip replacements by hardware‐in‐the‐loop simulation

A Geier, D Kluess, R Grawe… - Journal of …, 2017 - Wiley Online Library
Since dislocation of total hip replacements (THR) remains a clinical problem, its
mechanisms are still in the focus of research. Previous studies ignored the impact of soft …

Simulation of in vivo dynamics during robot assisted joint movement

E Bobrowitsch, A Lorenz, N Wülker, C Walter - BioMedical Engineering …, 2014 - Springer
Background Robots are very useful tools in orthopedic research. They can provide
force/torque controlled specimen motion with high repeatability and precision. A method to …

Einsatzgebiete der numerischen Simulation in der muskuloskelettalen Forschung und ihre Bedeutung für die Orthopädische Chirurgie.

D Kluess, C Hurschler, C Voigt, A Hölzer… - Der …, 2013 - search.ebscohost.com
Einsatzgebiete der numerischen Simulation in der muskuloskelettalen Forschung und ihre
Bedeutung für O Page 1 Orthopäde 2013 · 42:220–231 DOI 10.1007/s00132-012-1949-0 …