Performance evaluation of the Vereos PET/CT system according to the NEMA NU2-2012 standard

I Rausch, A Ruiz, I Valverde-Pascual… - Journal of Nuclear …, 2019 - Soc Nuclear Med
The aim of this study was to evaluate the physical performance of the Vereos whole-body
PET/CT system according to the National Electrical Manufacturers Association (NEMA) NU2 …

[HTML][HTML] Monte Carlo simulation of digital photon counting PET

J Salvadori, J Labour, F Odille, PY Marie, JN Badel… - EJNMMI physics, 2020 - Springer
Abstract A GATE Monte Carlo model of the Philips Vereos digital photon counting PET
imaging system using silicon photo-multiplier detectors was proposed. It was evaluated …

[HTML][HTML] Application of NEMA protocols to verify GATE models based on the Digital Biograph Vision and the Biograph Vision Quadra scanners

MM Peña-Acosta, S Gallardo, M Lorduy-Alós… - … für Medizinische Physik, 2024 - Elsevier
Abstract Purpose The Monte Carlo method is an effective tool to simulate and verify PET
systems. Furthermore, it can help in the design and optimization of new medical imaging …

A Monte Carlo simulation study of the impact of novel scintillation crystals on performance characteristics of PET scanners

A Ghabrial, D Franklin, H Zaidi - Physica medica, 2018 - Elsevier
Objective The purpose of this study is to validate a Monte Carlo simulation model for the
clinical Siemens Biograph mCT PET scanner using the GATE simulation toolkit, and to …

[HTML][HTML] Use of non-Gaussian time-of-flight kernels for image reconstruction of Monte Carlo simulated data of ultra-fast PET scanners

N Efthimiou, K Thielemans, E Emond, C Cawthorne… - EJNMMI physics, 2020 - Springer
Introduction Time-of-flight (TOF) positron emission tomography (PET) scanners can provide
significant benefits by improving the noise properties of reconstructed images. In order to …

Dictionary-based software for proton dose reconstruction and submilimetric range verification

VV Onecha, P Galve, P Ibáñez, C Freijo… - Physics in Medicine …, 2022 - iopscience.iop.org
Objective. This paper presents a new method for fast reconstruction (compatible with in-
beam use) of deposited dose during proton therapy using data acquired from a PET …

UMC-PET: a fast and flexible Monte Carlo PET simulator

P Galve, F Arias-Valcayo… - Physics in Medicine …, 2024 - iopscience.iop.org
Objective. The GPU-based Ultra-fast Monte Carlo positron emission tomography simulator
(UMC-PET) incorporates the physics of the emission, transport and detection of radiation in …

MCGPU-PET: An open-source real-time Monte Carlo PET simulator

JL Herraiz, A Lopez-Montes, A Badal - Computer Physics Communications, 2024 - Elsevier
Monte Carlo (MC) simulations are commonly used to model the emission, transmission,
and/or detection of radiation in Positron Emission Tomography (PET). In this work, we …

Super-iterative image reconstruction in PET

P Galve, JM Udias, A Lopez-Montes… - IEEE Transactions …, 2021 - ieeexplore.ieee.org
Despite its success in many biomedical applications, Positron Emission Tomography (PET)
has the drawback of typically having lower spatial resolution and higher noise respect to …

Monte Carlo techniques in nuclear medicine dosimetry

H Zaidi, P Andreo - Monte Carlo Calculations in Nuclear Medicine …, 2022 - iopscience.iop.org
In this chapter, the framework for the application of the Monte Carlo method to a wide range