Test of a single module of the J-PET scanner based on plastic scintillators

P Moskal, S Niedźwiecki, T Bednarski… - Nuclear Instruments and …, 2014 - Elsevier
Abstract A Time of Flight Positron Emission Tomography scanner based on plastic
scintillators is being developed at the Jagiellonian University by the J-PET collaboration …

Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

P Moskal, O Rundel, D Alfs, T Bednarski… - Physics in Medicine …, 2016 - iopscience.iop.org
Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-
PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the …

A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals

P Moskal, N Zoń, T Bednarski, P Białas… - Nuclear Instruments and …, 2015 - Elsevier
A novel method of hit time and hit position reconstruction in scintillator detectors is
described. The method is based on comparison of detector signals with results stored in a …

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

D Kamińska, A Gajos, E Czerwiński, D Alfs… - The European Physical …, 2016 - Springer
We present a study of the application of the Jagiellonian positron emission tomograph (J-
PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J …

Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom: a purely leptonic system

P Moskal, D Alfs, T Bednarski, P Białas… - … Physica Polonica. B, 2016 - ruj.uj.edu.pl
If Nature was utterly symmetric, the matter would not exist. Thus, we owe our existence to the
asymmetry between matter and anti-matter which must have appeared at the early stage of …

Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

L Raczyński, P Moskal, P Kowalski, W Wiślicki… - Nuclear Instruments and …, 2014 - Elsevier
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron
Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility …

Compressive sensing of signals generated in plastic scintillators in a novel J-PET instrument

L Raczyński, P Moskal, P Kowalski, W Wiślicki… - Nuclear Instruments and …, 2015 - Elsevier
The J-PET scanner, which allows for single bed imaging of the whole human body, is
currently under development at the Jagiellonian University. The discussed detector offers …

Sampling FEE and Trigger-less DAQ for the J-PET Scanner

G Korcyl, D Alfs, T Bednarski, P Białas… - arXiv preprint arXiv …, 2016 - arxiv.org
In this paper, we present a complete Data Acquisition System (DAQ) together with the
readout mechanisms for the J-PET tomography scanner. In general detector readout chain is …

Calculation of the time resolution of the J-PET tomograph using kernel density estimation

L Raczyński, W Wiślicki, W Krzemień… - Physics in Medicine …, 2017 - iopscience.iop.org
In this paper we estimate the time resolution of the J-PET scanner built from plastic
scintillators. We incorporate the method of signal processing using the Tikhonov …

Analysis framework for the J-PET scanner

W Krzemień, A Gajos, A Gruntowski, K Stola… - arXiv preprint arXiv …, 2015 - arxiv.org
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which
provides the tools to develop reconstruction and calibration procedures for PET tomography …