Fault location based on synchronized measurements: a comprehensive survey

AH Al-Mohammed, MA Abido - The Scientific World Journal, 2014 - Wiley Online Library
This paper presents a comprehensive survey on transmission and distribution fault location
algorithms that utilize synchronized measurements. Algorithms based on two‐end …

Determining minimum number and optimal placement of PMUs for fault observability in one‐terminal algorithms

ME Hamedani Golshan… - IET Generation …, 2018 - Wiley Online Library
One‐terminal algorithms utilise only measurements at one end of the transmission lines for
fault location, and thus, the required number of phasor measurement units (PMUs) is less …

A threshold free synchrophasor measurement based multi-terminal fault location algorithm

Y Cai, AD Rajapakse, NM Haleem, N Raju - International Journal of …, 2018 - Elsevier
A new impedance based fault location algorithm is proposed for a generic multi-terminal
transmission network consisting of a main line and tapped branches with no direct …

Dynamic fault locator for three‐terminal transmission lines for phasor measurement units

ZY He, XP Li, W He, YP Liu, S Zhang… - IET Generation …, 2013 - Wiley Online Library
The study presents a fault locator for three‐terminal transmission lines under dynamic
conditions such as power oscillation based on synchronised phasor measurement units …

PMU based adaptive zone settings of distance relays for protection of multi-terminal transmission lines

B Mallikarjuna, P Shanmukesh, D Anmol… - … and Control of …, 2018 - ieeexplore.ieee.org
This paper proposes Phasor Measurement Unit (PMU) based adaptive zone settings of
distance relays (PAZSD) methodology for protection of multi-terminal transmission lines …

Method for fault location in electric power lines

P Balcerek, M Fulczyk, E Rosolowski… - US Patent …, 2012 - Google Patents
Ying-Hong Lin et al:" A New Fault Locator for Three-Terminal Transmission Lines. Using
Two-Terminal Synchronized Voltage and Current Phasors”, IEEE Transactions on Power …

A novel wide-area fault location algorithm based on fault model

J Ma, J Li, Z Wang, Q Yang - 2010 Asia-Pacific Power and …, 2010 - ieeexplore.ieee.org
A novel wide-area fault location algorithm is proposed in this paper. Fault model is
developed in super-imposed network, and then based on network correlation coefficient …

[引用][C] T 型高压输电线路故障测距

施世鸿, 何奔腾, 张武军 - 中国电机工程学报, 2008

[引用][C] 基于同步相量测量的N 端输电线路故障测距新算法

王增平, 林富洪 - 电网技术, 2010

[引用][C] T 型输电线路非同步数据故障测距新算法

施世鸿, 何奔腾 - 电力自动化设备, 2008