Squat exercise abnormality detection by analyzing joint angle for knee osteoarthritis rehabilitation

MFA Hassan, MA Zulkifley, A Hussain - Jurnal Teknologi, 2015 - journals.utm.my
Normally, osteoarthritic knee patients experienced 1) difficulties controlling their fine motors,
2) lack of muscle strength, and 3) limited range of motion. The limitations can be improved …

Longitudinal quantification of eye-movement impairments after pontine hemorrhage

M Suner, GT Prusky, JB Carmel, NJ Hill - Frontiers in Neurology, 2017 - frontiersin.org
Introduction We report a case of hypertrophic olivary degeneration due to pontine
hemorrhage. A 59-year-old male with untreated hypertension suffered a primary pontine …

Motion capture camera system for measurement of head and shoulders position

J Hejda, P Kutilek, J Hozman, R Cerny - Biomedical Engineering …, 2012 - degruyter.com
The objective of our study was to develop a technique for precise head and shoulder
posture measurement or, in other words, for measuring the native position of the head and …

System for precise measurement of head and shoulders position

J Hejda, P Kutilek, J Hozman, R Černý - XIII Mediterranean Conference on …, 2014 - Springer
The objective of our study is to develop a technique for precise head and shoulders posture
measurement or, in other words, for measuring the native position of the head and shoulders …

Differences in evaluation methods of trunk sway using different MoCap systems

P Kutilek, V Socha, O Cakrt… - Acta of bioengineering …, 2014 - yadda.icm.edu.pl
The position of the trunk can be negatively influenced by many diseases. Several methods
can be used for identifying defects in balance and coordination as a result of pathology of …

Head movement analysis based on areas of convex hull and confidence ellipse obtained using two motion capture systems

P Kutilek, V Socha, O Cakrt, R Cerny - Journal of Medical and Biological …, 2015 - Springer
This paper proposes two methods that are potentially suitable for the analysis of movements
and quantitative assessment of the postural stability of the head. A camera system and a …

A technique for quantifying the relative angular movement of the head and shoulders

P Kutilek, P Volf, J Hejda, J Hozman… - EMBEC & NBC 2017 …, 2018 - Springer
The objective of this study was to develop a method for quantifying the relative angular
movements of the head and shoulders. To analyze and quantify the movement of …

Comparative measurement of the head orientation using camera system and gyroscope system

P Kutilek, O Cakrt, J Hejda, R Cerny - XIII Mediterranean Conference on …, 2014 - Springer
The aim of article is to compare two fundamentally different MoCap systems used to
measure head orientation. We used IR medical camera and one 3DOF orientation tracker …

Comparative measurements of head angular movements using a camera system and a gyroscope system

V Socha, P Kutilek, O Cakrt, R Cerny - Acta Polytechnica, 2014 - ojs.cvut.cz
Assessments of body-segment angular movements are very important in the rehabilitation
process. Head angular movements are measured and analyzed for use in studies of stability …

Evaluation of the relative position of the head and shoulders in neurological practice

P Kutilek, J Hejda, V Socha, K Vlckova… - … on Applied Electronics, 2014 - ieeexplore.ieee.org
The article is dealing with the study of stability and posture by measuring and analyzing the
angular movements of the head and shoulders. In neurological practice, however, this …