Current indications for hip resurfacing arthroplasty in 2016

R Sershon, R Balkissoon, CJD Valle - Current reviews in musculoskeletal …, 2016 - Springer
Hip resurfacing arthroplasty (HRA) is an alternative to conventional, stemmed total hip
arthroplasty (THA). The best reported results are young, active patients with good bone stock …

The effectiveness of blood metal ions in identifying patients with unilateral Birmingham Hip Resurfacing and Corail-Pinnacle metal-on-metal hip implants at risk of …

GS Matharu, F Berryman, L Brash, PB Pynsent… - JBJS, 2016 - journals.lww.com
Background: We investigated whether blood metal ions could effectively identify patients
with metal-on-metal hip implants with two common designs (Birmingham Hip Resurfacing …

Correlation of serum metal ion levels with pathological changes of ARMD in failed metal-on-metal-hip-resurfacing arthroplasties

G Grammatopoulos, M Munemoto, A Pollalis… - Archives of orthopaedic …, 2017 - Springer
Background Metal-on-metal-hip-resurfacing arthroplasties (MoMHRAs) have been
associated with an increased failure rates due to an adverse-response-to-metal-debris …

What is appropriate surveillance for metal-on-metal hip arthroplasty patients? A clinical update

GS Matharu, A Judge, A Eskelinen, DW Murray… - Acta …, 2018 - Taylor & Francis
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or
greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory …

Can blood metal ion levels be used to identify patients with bilateral Birmingham Hip Resurfacings who are at risk of adverse reactions to metal debris?

GS Matharu, F Berryman, L Brash… - The Bone & Joint …, 2016 - boneandjoint.org.uk
Aims We investigated whether blood metal ion levels could effectively identify patients with
bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal …

Patient obesity influences pelvic lift during cup insertion in total hip arthroplasty through a lateral transgluteal approach in supine position

S Brodt, D Nowack, B Jacob, L Krakow… - The Journal of …, 2017 - Elsevier
Background Movement of the pelvis during implantation of total hip arthroplasty (THA) has a
major influence on the positioning of the acetabular cup. Strong traction caused by retractors …

Patient and radiographic factors help to predict metal-on-metal hip resurfacings with evidence of a pseudotumor

GS Matharu, O Blanshard, K Dhaliwal, A Judge… - JBJS, 2017 - journals.lww.com
Background: The role of radiographs in the follow-up of patients with metal-on-metal hip
resurfacing (MoMHR) implants is unclear. We investigated whether a combination of patient …

[HTML][HTML] Comparing 1-year and 10-year whole blood metal ion results following Birmingham hip resurfacing for osteoarthritis

SJW Kearns, J Bourget-Murray… - Canadian Journal of …, 2022 - ncbi.nlm.nih.gov
Study design We retrospectively studied consecutive patients who received a BHR (Smith &
Nephew Orthopaedics Ltd, Warwick, UK) for osteoarthritis with a minimum 10-year follow-up …

Careful patient selection together with optimal implant positioning may reduce but does not eliminate the risk of elevated serum cobalt and chrome levels following …

A Oxblom, H Hedlund, R Itayem… - Hip …, 2023 - journals.sagepub.com
Background: Elevated serum chrome (sCr) and cobalt (sCo) concentrations are associated
with local tissue adverse reactions to metal debris following metal-on-metal hip resurfacing …

How much does a Medical and Healthcare Products Regulatory Agency medical device alert for metal-on-metal hip arthroplasty patients really cost?

RS Nandra, U Ahmed, F Berryman, L Brash… - Hip …, 2022 - journals.sagepub.com
Background: Many worldwide regulatory authorities recommend regular surveillance of
metal-on-metal hip arthroplasty patients given high failure rates. However, concerns have …