A review of methods for non-invasive heart rate measurement on wrist

NDP Ferreira, C Gehin, B Massot - Irbm, 2021 - Elsevier
When evaluating general health condition on a patient, heart rate is an essential indicator as
it is directly representative of the cardiac system state. Continuous measurement methods of …

Review of self-injection-locked radar systems for noncontact detection of vital signs

FK Wang, CTM Wu, TS Horng… - IEEE Journal of …, 2020 - ieeexplore.ieee.org
In recent decades, wireless healthcare detection has been demonstrated to be an efficient
method for monitoring the health condition of targets; it has involved the detection of motion …

Application of non-contact sensors for health monitoring in hospitals: a narrative review

YJ Choo, GW Lee, JS Moon, MC Chang - Frontiers in Medicine, 2024 - frontiersin.org
The continuous monitoring of the health status of patients is essential for the effective
monitoring of disease progression and the management of symptoms. Recently, health …

Acoustic sensing as a novel wearable approach for cardiac monitoring at the wrist

P Sharma, SA Imtiaz, E Rodriguez-Villegas - Scientific reports, 2019 - nature.com
This paper introduces the concept of using acoustic sensing over the radial artery to extract
cardiac parameters for continuous vital sign monitoring. It proposes a novel measurement …

A wearable self-injection-locked sensor with active integrated antenna and differentiator-based envelope detector for vital-sign detection from chest wall and wrist

CH Tseng, LT Yu, JK Huang… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
This paper presents a new wearable self-injection-locked sensor with a self-oscillating
active integrated antenna (AIA) and a differentiator-based envelope detector for detecting …

A novel microwave phased-and perturbation-injection-locked sensor with self-oscillating complementary split-ring resonator for finger and wrist pulse detection

CH Tseng, CZ Wu - IEEE Transactions on Microwave Theory …, 2020 - ieeexplore.ieee.org
In this article, a novel microwave phased-and perturbation-injection-locked (PPIL) sensor
with a self-oscillating complementary split-ring resonator (SO-CSRR) is proposed for finger …

Super-regenerative oscillator-based high-sensitivity radar architecture for motion sensing and vital sign detection

Y Yuan, AYK Chen, CTM Wu - IEEE Transactions on Microwave …, 2021 - ieeexplore.ieee.org
A radar sensor architecture based on a super-regenerative oscillator (SRO) with very high
sensitivity is presented for vital sign detection and motion sensing. As a proof of concept, the …

A Teenager Physical Fitness Evaluation Model Based on 1D-CNN with LSTM and Wearable Running PPG Recordings

J Guo, B Wan, S Zheng, A Song, W Huang - Biosensors, 2022 - mdpi.com
People attach greater importance to the physical health of teenagers because adolescence
is a critical period for the healthy development of the human body. With the progress of …

Noncontact pulse transit time measurement using a single-frequency continuous-wave radar

MC Tang, CM Liao, FK Wang… - 2018 IEEE/MTT-S …, 2018 - ieeexplore.ieee.org
This paper presents a single-frequency continuous-wave (CW) radar that operates
concurrently with two different modes to measure pulse transmit time (PTT) without contact …

A novel non-contact self-injection-locked radar for vital sign sensing and body movement monitoring in COVID-19 isolation ward

CY Tsai, NC Chang, HC Fang, YC Chen… - Journal of medical …, 2020 - Springer
Abstract Background The outbreak of Coronavirus disease (COVID-19) pandemic has
become the most serious global health issue. Isolation policy in hospitals is one of the most …