Studies on a dual energy RF electron linac

B Nayak, D Bhattacharjee… - Journal of Instrumentation, 2019 - iopscience.iop.org
Beam dynamics study of a dual energy (6/3.5 MeV) standing wave RF electron Linac as a
cargo scanner is carried out in the code ASTRA. This paper discusses a detailed study on …

Multiphysics analysis of side-coupled RF cavity

MM Kejani, F Ghasemi, FA Davani… - Journal of …, 2019 - iopscience.iop.org
By changing the resonant frequency of the cavity due to the power dissipation in its wall, the
impedance matching will impair and the power will reflect. The acceptable frequency shift …

Development of a novel approach for construction of high gradient braze-free S-band cavities

M Aghayan, SF Masoudi, F Ghasemi, W Wuensch… - Scientific Reports, 2021 - nature.com
Vacuum breakdown is one of the main limitations to the operating accelerating gradient in
radio frequency linear accelerators. Recent studies of copper cavities have been shown that …

Design and implementation of control system for IPM e-LINAC

M Shirshekan, O Hasanpour, SS Hajari… - Journal of Theoretical …, 2024 - oiccpress.com
The construction of a LINAC facility to provide hands-on experience has been under way at
Institute for Research in Fundamental Sciences (IPM). The LINAC, which accelerates an …

On the feasibility of using an 8 MeV electron linac for beam designing in BNCT of head tumors

FS Rasouli - Journal of Radioanalytical and Nuclear Chemistry, 2022 - Springer
The continuing need for providing improved facilities for radiation therapies has made
investigation of various neutron sources an interesting subject of study. The so-called …

Design of high gradient S-band cavity and coupler

SM Aghayan, SF Masoudi, SH Shaker… - Journal of Nuclear …, 2022 - jonsat.nstri.ir
Studies on high gradient linear accelerators are among the new areas in the field of
accelerators. The most important factor that limits the electric field gradient in linear …

Dimensional analysis of high gradient RF cavity considering shrink-fit construction method

M Aghayan, SF Masoudi, F Ghgasemi… - Radiation Physics and …, 2021 - rpe.kntu.ac.ir
Advantage of non-brazing methods in manufacturing of cavities has been considered in high
gradient studies because of the softening of copper by brazing cavities at high temperatures …

Spectrometer design for diagnostics in a wide range of energy at a linear accelerator

S Kasaei, SS Hajari, M Bahrami… - Journal of …, 2018 - iopscience.iop.org
A spectrometer design has been presented for the electron linear accelerator at Institute for
Research in Fundamental Sciences (IPM), Tehran, Iran. The energy of the linac is 8 MeV …

[HTML][HTML] A DIAGNOSTICS BOX FOR THE LINEAR ACCELERATOR OF INSTI-TUTE FOR RESEARCH IN FUNDAMENTAL SCIENCES (IPM)

SS Hajari, S Ahmadiannamin, M Bahrami… - researchgate.net
The IPM linac is an 8 MeV (up gradable to 11 MeV) electron linear accelerator under
development at Institute for Research in Fundamental Sciences, Tehran, Iran. The design …