[PDF][PDF] Investigation of overvoltage on square, rectangular and L-shaped ground grids of high voltage substations by ATP/EMTP.

K Luewattana, P Rattanasena - International Journal of Electrical & …, 2021 - academia.edu
Ground grid system is important for preventing the hazardous effects of overvoltage in high
voltage substations due to fault current perhaps from lightning strike or device malfunction …

Approximate model for ground inhomogeneity with rectangular cross section: application to analysis of grounding systems

DD Vuckovic, NN Cvetkovic, MS Stojanovic… - Electrical …, 2018 - Springer
A procedure for characterization of lighting pole grounding systems placed inside and/or
outside the road is presented in the paper. The road is treated as ground inhomogeneity of …

Transient behavior of a system composed of conductive thin wire structures excited by harmonic and lightning type signals

E Faleiro Usanos, G Asensio Madrid… - Journal of …, 2014 - oa.upm.es
The transient response of a system of independent electrodes buried in a semi-infinite
conducting medium is studied. Using a simple and versatile numerical scheme written by the …

การ ศึกษา ผล กระทบ จาก แรง ดัน เกิน ที่ เกิด ขึ้น บน ระบบ กราว ด์ กริด รูป แบบ Rectangular ซึ่ง มี แท่ง หลัก ดิน แบบ กระจาย ของ สถานี ไฟฟ้า แรง สูง

กรุง ลือ วัฒนา - Kasem Bundit Engineering Journal, 2020 - ph01.tci-thaijo.org
This research aimed to study the effects of overvoltage that occurring on the rectangular
ground grid system of high voltage substation, of which ground rods were distributed in …

[PDF][PDF] ANALISIS PENGARUH PENTANAHAN TERHADAP JUMLAH ISOLATOR TRANSMISI SUTT JAJAR–PEDAN

KADINUR ICHSAN - core.ac.uk
Tegangan lebih akibat surja petir pada saluran transmisi listrik merupakan salah satu
penyebab terjadinya gangguan yang dapat menimbulkan kegagalan proteksi dan …

Analisis Pengaruh Pentanahan Terhadap Jumlah Isolator Transmisi Sutt Jajar–Pedan

K Adi Nur Ichsan, ST Agus Supardi - 2018 - eprints.ums.ac.id
Tegangan lebih akibat surja petir pada saluran transmisi listrik merupakan salah satu
penyebab terjadinya gangguan yang dapat menimbulkan kegagalan proteksi dan …

[PDF][PDF] TRANSIENT BEHAVIOROF A SYSTEM COMPOSED OF CONDUCTIVE THIN WIRE STRUCTURE EXCITED BY HARMONIC AND LIGHTNING TYPE SIGNALS

S Kumar, V Kumar, D Kumar, VK Mandal - academia.edu
The transient response of a system of independent electrodes buried in a semi-infinite
conducting medium is studied. Using a simple and versatile numerical scheme written by the …

[PDF][PDF] NENAD CVETKOVIĆ DRAGAN VUČKOVIĆ2

D KRSTIĆ - practice - znrfak.ni.ac.rs
The pillars' grounding system formed of one and two horizontal square-shaped wire
electrodes and an iron armature connected to the main grounding connector are analyzed in …

[引用][C] Foundational Steel Reinforcement Earthing Evaluation: Case of Ogomudia Electrical/Electronics Laboratory Building Extension, Federal University Of …

MO Oyeleye, TO Ale - FUTA JOURNAL OF ENGINEERING AND …, 2019