[HTML][HTML] A review of total harmonic distortion factors for the measurement of harmonic and interharmonic pollution in modern power systems

A Arranz-Gimon, A Zorita-Lamadrid, D Morinigo-Sotelo… - Energies, 2021 - mdpi.com
Harmonic distortion is one of the disturbances that most affects the quality of the electrical
system. The widespread use of power electronic systems, especially power converters, has …

Comparison of measurement methods for 2–150-kHz conducted emissions in power networks

D Ritzmann, S Lodetti, D de la Vega… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
This article presents a comparison of measurement methods for current and voltage
distortions in low-voltage networks in the frequency range from 2 to 150 kHz …

Comparison of measurement methods for the frequency range 2–150 kHz (supraharmonics) based on the present standards framework

V Khokhlov, J Meyer, A Grevener, T Busatto… - IEEE …, 2020 - ieeexplore.ieee.org
Advances in power electronics, increasing share of renewables in the energy system and e-
mobility cause an increase of disturbances in the frequency range 2-150 kHz, also known as …

A light measurement method for 9–150 kHz disturbances in power grids comparable to CISPR quasi-peak

A Gallarreta, I Fernández, D Ritzmann… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
This study proposes a novel measurement method to assess the disturbances in the
electrical grid for the CISPR Band A (9–150 kHz), as no normative grid measurement …

[PDF][PDF] Problem of total harmonic distortion measurement performed by smart energy meters

P Kuwałek, G Wiczy - Measurement science review, 2022 - intapi.sciendo.com
Currently, electricity is treated as commodity that should be delivered from a distributor to a
consumer with a certain quality. The power quality is defined by the set of measures with …

A new advanced method for an accurate assessment of harmonic and supraharmonic distortion in power system waveforms

G Carpinelli, A Bracale, P Varilone, T Sikorski… - IEEE …, 2021 - ieeexplore.ieee.org
Waveforms distortion is a pressing concern in Smart Grids where a massive presence of
new technologies in distributed energy resources and in advanced smart metering systems …

[HTML][HTML] Emission assessment of single-phase switch-mode PFC loads up to 150 kHz: Experimental analysis and modelling

AJ Collin, J Drapela, R Langella, A Testa - Electric Power Systems …, 2023 - Elsevier
The ongoing integration of new power electronic interfaces is increasing emissions in the
frequency range between 2 and 150 kHz. This paper considers the emission assessment …

A robust PAST-based ESPRIT algorithm with variable forgetting factor and regularization for frequencies/harmonics estimation in impulsive noise

JQ Lin, SC Chan, HC Wu - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The estimation of signal parameters via the rotational invariance techniques (ESPRIT)
algorithm is an efficient method for frequency estimation, and it has many applications in …

The role of supply conditions on the measurement of high-frequency emissions

AJ Collin, A Delle Femine, C Landi… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
A standardized measurement procedure and source specification for laboratory high-
frequency (HF, 2-150 kHz) emissions tests of low-voltage (LV) electronic equipment are still …

[HTML][HTML] Performance analysis of matrix pencil method applied to high-resolution measurement of supraharmonics

K Li, W Zhao, S Li, S Huang - Energies, 2023 - mdpi.com
Supraharmonics emitted by power electronic equipment will cause electromagnetic
interference. However, there is no uniform standard for the measurement of supraharmonics …