Comparison of gamma ray localization using system matrixes obtained by either MCNP simulations or ray-driven calculations for a coded-aperture imaging system

M Jeong, MD Hammig - Nuclear Instruments and Methods in Physics …, 2020 - Elsevier
A coded-aperture system based on a large-area silicon photo-multiplier (SiPM) coupled with
inorganic scintillator was developed for the gamma ray localization in the field of nuclear …

A Spherical Active Coded Aperture for Gamma-Ray Imaging

D Hellfeld, P Barton, D Gunter… - … on Nuclear Science, 2017 - ieeexplore.ieee.org
Gamma-ray imaging facilitates the efficient detection, characterization, and localization of
compact radioactive sources in cluttered environments. Fieldable detector systems …

Comparison between pixelated scintillators: CsI (Tl), LaCl 3 (Ce) and LYSO (Ce) when coupled to a silicon photomultipliers array

M Jeong, B Van, BT Wells, JD Lawrence… - Nuclear Instruments and …, 2018 - Elsevier
A large area SiPM array is individually coupled to five different types of scintillators in and
each is evaluated for the development of a coded aperture imaging system. In order to …

Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study

X Liang, L Shuai, Y Liu, X Li, L Kong, Q Wei… - Nuclear Instruments and …, 2022 - Elsevier
In the study of this paper, based on the symmetry of regular icosahedron, a spherical
detector system for 4 π field-of-view (FOV) gamma imaging was proposed based on 80 …

Row–Column readout method to mitigate radiographic-image blurring from multipixel events in a coded-aperture imaging system

J Boo, MD Hammig, M Jeong - IEEE Transactions on Nuclear …, 2021 - ieeexplore.ieee.org
In order to improve the image quality of a coded-aperture-based gamma-ray imaging
apparatus, a method for removing Compton scattered and other multipixel events is …

[HTML][HTML] MCNP-polimi simulation for the compressed-sensing based reconstruction in a coded-aperture imaging CAI extended to partially-coded field-of-view

M Jeong, G Kim - Nuclear Engineering and Technology, 2021 - Elsevier
This paper deals with accurate image reconstruction of gamma camera using a coded-
aperture mask based on pixel-type CsI (Tl) scintillator coupled with silicon photomultipliers …

Applications of digitized 3-D position-sensitive CdZnTe spectrometers for national security and nuclear nonproliferation

M Streicher - 2017 - deepblue.lib.umich.edu
A nuclear weapon detonation remains one of the gravest threats to the global community.
Although the likelihood of a nuclear event remains small, the economic and political …

Nuclear security science

D LaGraffe - Handbook of Security Science, 2022 - Springer
This chapter provides a survey of the science and technology important to nuclear security.
A wide range of military, intelligence, law enforcement, diplomatic, policy, and cooperative …

Time-encoded thermal neutron imaging using large-volume pixelated CdZnTe detectors

S Brown - 2017 - deepblue.lib.umich.edu
CdZnTe detectors are commonly used for room-temperature gamma-ray spectroscopy and
imaging in a variety of applications including nuclear security, nuclear medicine, and space …

[PDF][PDF] Academic Theses and Dissertations that Depend on the MCNP Code

JA Kulesza - Los Alamos National Laboratory, Los Alamos, New …, 2022 - mcnp.lanl.gov
This memo provides a listing of graduate-level theses and dissertations that rely on the
MCNP code. The documents may depend on the code's data, documentation, and/or …