An analytical approach to detect generator loss of excitation based on internal voltage calculation

M Abedini, M Sanaye-Pasand… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
The excitation system of a synchronous generator has a major role in proper operation and
control of the generator. Loss of excitation (LOE) may cause harmful effects on the both …

Analytical technique for synchronous generator loss‐of‐excitation protection

N Noroozi, H Yaghobi… - IET Generation …, 2017 - Wiley Online Library
This study introduces a new analytical approach for the detection of loss of excitation (LOE)
in a synchronous generator that uses only one local variable. The proposed method applies …

A loss-of-field detection relay based on rotor signals estimation

M Abedini, M Sanaye-Pasand… - … on Power Delivery, 2017 - ieeexplore.ieee.org
This paper 1) introduces a new approach for dependable and secure detection of loss-of-
field (LOF) events based on estimating rotor signals, 2) implements digital algorithm of the …

A secure and setting-free technique to detect loss of field in synchronous generators

A Hasani, F Haghjoo - IEEE Transactions on Energy …, 2017 - ieeexplore.ieee.org
Loss-of-field (LOF) phenomenon in synchronous generators may cause equipment damage
and voltage drop in the power system, which can be terminated to a blackout. Conventional …

A novel loss-of-excitation protection strategy based on reactive power increment of synchronous generators

A Rostami, N Rezaei - IEEE Transactions on Power Delivery, 2021 - ieeexplore.ieee.org
This paper outlines a novel loss of excitation (LOE) protection scheme for synchronous
generators (SGs) based on reactive power increment (RPI) strategy and tracking the …

Loss of excitation detection in synchronous generators based on dynamic state estimation

P Marchi, PG Estevez, F Messina… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
In this article, we present a new approach to the detection of Loss-Of-Excitation (LOE), a
typical failure of synchronous generators. Unlike most of the algorithms proposed in the …

A relay logic for total and partial loss of excitation protection in synchronous generators

M Rasoulpour, T Amraee… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Loss of Excitation (LOE) is an important fault in synchronous generators which may cause
the generator outage due to out-of-step (OS) conditions. Since the LOE protective relays act …

A reliable loss of excitation protection technique based on EPFA for synchronous generators

HA Abd el-Ghany, ES Ahmed… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Loss of excitation (LOE) is one of the most important issues of synchronous alternators,
which may be a source of genuine harms and could lead to power system instability. The …

A current-based differential technique to detect loss of field in synchronous generators

A Hasani, F Haghjoo, FMF Da Silva… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
A new approach for generator loss of field (LOF) protection is proposed by estimating the
field current based on the generator measurable parameters. The main idea of the proposed …

A new adaptive impedance-based LOE protection of synchronous generator in the presence of STATCOM

H Yaghobi - IEEE Transactions on Power Delivery, 2017 - ieeexplore.ieee.org
This paper presents a new adaptive distance function for loss of excitation (LOE) protection
of synchronous generator in the presence of STATCOM. Nowadays, the Berdy distance …