X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages

GE Campillo-Rivera, CO Torres-Cortes… - Radiation Physics and …, 2021 - Elsevier
The energy distribution of photons (spectrum) produced in X-ray generators, or X-ray tubes,
depends on current, voltage and the target/filter combination; in turn, the dose depends on …

Doses and spectra, of leaking-out and scattered photons from X-ray tubes used in dentistry

HR Vega-Carrillo, J Vazquez-Bañuelos… - Applied Radiation and …, 2022 - Elsevier
Diagnosis by X-ray image are procedures widely used to improve the diagnosis or to follow
the evolution of a medical procedure, also are used to support the cancer treatment with …

Spectra, ΓH*(10) and ΓKa produced by X-ray tubes, with Mo and Rh targets, in the diagnostic energy range

HR Vega-Carrillo, GE Campillo-Rivera… - Radiation Physics and …, 2022 - Elsevier
Voltage, current, target and filter in X-ray tubes define the X-ray spectrum; in turn, any
dosimetric quantity depends on the spectrum. In the operation of an X-ray generator the …

Phantom dosimetry and cancer risks estimation undergoing 6 MV photon beam by an Elekta SL-25 linac

R Khabaz - Applied Radiation and Isotopes, 2020 - Elsevier
The High-energy linear accelerator (linac) is a valuable tool and the most commonly used
devices for external beam radiation treatments in subjects suffer from cancer. To estimate …

Validation of ΓKa for Diagnostic Radiography in three different hospitals in the Lambayeque region, Peru

HER Nomura, MVV Arteaga, SLA Peralta… - Radiation Physics and …, 2024 - Elsevier
Air Kerma was measured and compared with calculated air Kerma aiming to validate the
use of air Kerma gamma factors. The air Kerma was measured in radiology departments in …

Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study

H Vafapour, S Panah, P Rafiepour… - Radiation Protection …, 2025 - academic.oup.com
Radiation protection in dental radiography can be achieved by adjusting the image field
size, exposure, and filtration parameters, and using protective lead shields. The aim of this …

Exposición a rayos X del operador de equipos radiográficos portátiles de mano en odontología con distintas angulaciones verticales

C Fuentealba Muñoz… - Avances en …, 2024 - SciELO Espana
Introducción: La radiación retrodispersa es la causa principal de irradiación al operador de
equipos radiográficos portátiles de mano en odontología (ERPM). Su uso correcto incluye …

Estimation of doses absorbed by the thyroid and salivary glands, eyes, and brains of pediatric dental patients

WR Freire, AT Machado, GB Guimarães… - Radiation …, 2024 - Elsevier
In addition to the quality of the image, radiological protection of the patient must be
considered to ensure an adequate diagnosis in dental radiology, especially in regard to …

Assessment of Kerma coefficients for OSL dosimeters by analytical and Monte Carlo approaches

R Khabaz, HR Vega-Carrillo - Radiation Physics and Chemistry, 2020 - Elsevier
In optically stimulated luminescent dosimeters (OSLD), the intensity of luminescent is a
function of the dose of radiation absorbed and then it may be utilized as the basis of a …

Spectra, fluence and absorbed doses in sensitive organs due to scattered X-rays during a chest CT

J Vazquez-Bañuelos, GE Campillo-Rivera… - Applied Radiation and …, 2023 - Elsevier
The use of ionizing radiation for the treatment and diagnosis of diseases is becoming more
frequent. The technologies associated with diagnostic imaging are constantly evolving …