Dynamic voltage restore based on switched-capacitor multilevel inverter with ability to compensate for voltage drop, harmonics, and unbalancing simultaneously

M Ghodsi, SM Barakati, JM Guerrero… - Electric Power Systems …, 2022 - Elsevier
The voltage harmonics and voltage unbalance, as well as voltage drop due to the electrical
faults, can damage the sensitive loads. Various voltage compensators, such as the series …

An online UPS system that eliminates the inrush current phenomenon while feeding multiple load transformers

SSH Bukhari, TA Lipo, B Kwon - IEEE Transactions on Industry …, 2016 - ieeexplore.ieee.org
Numerous industrial facilities involve the installation of load transformers with their
respective loads. As these loads are engaged and disengaged, their transformers are also …

Design, control and monitoring of an offline mobile battery energy storage system for a typical malaysian household load using PLC

N Mohammed, KA Danapalasingam… - … Journal of Power …, 2018 - research.monash.edu
Battery energy storage system (BESS) is used in many practical applications including unin-
terruptible power supplies (UPS), portable devices, electrical vehicles and renewable …

A single-phase line-interactive UPS system for transformer-coupled loading conditions

SSH Bukhari, JS Ro - IEEE Access, 2020 - ieeexplore.ieee.org
A line-interactive uninterruptible power supply (UPS) system is one of the important
installations implemented by industrial users to provide continuous power to sensitive …

[HTML][HTML] Digital soft start implementation for minimizing start up transients in high power DAB-IBDC converter

P Sathishkumar, TNV Krishna, Himanshu, MA Khan… - Energies, 2018 - mdpi.com
The dual active bridge isolated bidirectional DC-DC converter (DAB-IBDC) is one of the
prime converters used in dual active bridge renewable energy storage system (RESS) …

A sag compensator that eliminates the possibility of inrush current while powering transformer-coupled loads

SSH Bukhari, S Atiq, B Kwon - IEEE Journal of Emerging and …, 2017 - ieeexplore.ieee.org
Sags are the foremost power quality problem encountered by industrial consumers because
they frequently cause the interruption of manufacturing processes, which can result in a …

Online failure diagnostic in full-bridge module for optimum setup of an IGBT-based multilevel inverter

JC Iglesias-Rojas, E Velázquez-Lozada… - Energies, 2022 - mdpi.com
An online failure diagnostic test is essential to ensure the robustness and reliability of high-
powered systems. Furthermore, the overall design must comprise diagnostic strategies to …

Standardized Impedance: Microgrid Perspective for Inrush Current Compliance

A Matthee, N Moonen, F Leferink - … International Symposium on …, 2022 - ieeexplore.ieee.org
With accelerating adoption of non-linear power electronics devices as well as the trend of
distributed generation and microgrids, inrush and transient switching currents are not …

Asymmetrical fault correction for the sensitive loads using a current regulated voltage source inverter

SSH Bukhari, S Atiq, TA Lipo, B Kwon - Energies, 2016 - mdpi.com
Numerous industrial applications involve loads that are very sensitive to electrical supply
instabilities. These instances involve various types of voltage imbalances as well as more …

An optimized disturbance observer based digital deadbeat control technique for three-phase voltage source inverter

MAU Rasool, MM Khan, MT Faiz, S Tahir… - Proceedings of the 2018 …, 2018 - dl.acm.org
In this paper, a digital deadbeat control technique based on a disturbance observer is
presented to facilitate the control of a three-phase voltage source inverter (VSI). This control …