[DOC][DOC] Graphite electrode potentiometric sensor modified by surface imprinted silica gel to measure valproic acid

M Vardini, N Abbasi, A Kaviani, M Ahmadi… - Chemical …, 2022 - researchgate.net
The aim of the study was to produce a Polyvinyl chloride-based membrane containing a
polymer imprinted with a valproic acid molecule which was directly coated on a graphite …

Mercury (II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base

MH Mashhadizadeh, I Sheikhshoaie - Talanta, 2003 - Elsevier
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg (II) ions
was prepared by using bis [5-((4-nitrophenyl) azo salicylaldehyde)](BNAS) as a suitable …

Carbon paste electrodes in potentiometry: the state of the art and applications in modern electroanalysis (a review)

Z Stanić, S Girousi - Sensing in electroanalysis. K. Kalcher, R. Metelka, I …, 2011 - dk.upce.cz
The development of chemical sensors has received widespread attention during the past
two decades because of their extensive use in environmental monitoring and clinical …

Developments in synthesis, characterization and applications of tin (IV) based composite ion exchangers: a review

Alimuddin, SA Khan - Journal of Coordination Chemistry, 2024 - Taylor & Francis
Composite ion exchangers are studied extensively due to their numerous applications.
These include antimicrobial agents, photocatalysts for dye degradation and ion selective …

A novel iron (III) selective membrane electrode based on benzo-18-crown-6 crown ether and its applications

G Ekmekci, D Uzun, G Somer, Ş Kalaycı - Journal of membrane science, 2007 - Elsevier
A new membrane electrode selective to iron (III)(in FeCl4− structure) has been developed
based on crown ether. The electrode consisted of trans-dinitro-dibenzo-18-6 crown ether as …

Preparation of a new solid state fluoride ion selective electrode and application

G Somer, Ş Kalaycı, İ Başak - Talanta, 2010 - Elsevier
A new solid state fluoride ion selective electrode composed of 70% Ag2S, 10% Cu2S and
20% CaF2 has been developed. An analytically useful potential change occurred, from 1× …

Analysis of halogens in wastewater with a new prepared ion selective electrode

S Kalayci - Monatshefte für Chemie-Chemical Monthly, 2022 - Springer
Ion selective electrode can rapidly, sensitively detect their corresponding ions and are
suitable for field testing. Chloride, fluoride, iodide and bromide ions were analyzed using the …

Voltammetric Determination of Mercury (II) at Poly (3‐hexylthiophene) Film Electrode. Effect of Halide Ions

U Tamer, T Oymak, N Ertaş - Electroanalysis: An International …, 2007 - Wiley Online Library
The well‐known method for the determination of mercury (II), which is based on the anodic
stripping voltammetry of mercury (II), has been adapted for applications at the thin film poly …

A mercury ion selective electrode based on poly-o-toluidine Zr (IV) tungstate composite membrane

M Naushad, TA Rangreez, ZA ALOthman - Journal of Electroanalytical …, 2014 - Elsevier
A Hg 2+ ion selective membrane electrode based on poly-o-toluidine Zr (IV) tungstate
composite cation exchange material was fabricated using solution casting method. The …

Iodide-selective membrane electrode based on salophen complex of cobalt (III)

HR Zare, F Memarzadeh, A Gorji… - Journal of the Brazilian …, 2005 - SciELO Brasil
A highly selective PVC membrane electrode based on a cobalt-salophen complex was
prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for …