Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: a review from NRG …

ED Brandner, IJ Chetty, TG Giaddui, Y Xiao… - Medical …, 2017 - Wiley Online Library
The efficacy of stereotactic body radiotherapy (SBRT) has been well demonstrated.
However, it presents unique challenges for accurate planning and delivery especially in the …

Motion in radiotherapy: photon therapy

SS Korreman - Physics in Medicine & Biology, 2012 - iopscience.iop.org
This review considers the management of motion in photon radiation therapy. An overview is
given of magnitudes and variability of motion of various structures and organs, and how the …

AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapy

PJ Keall, A Sawant, RI Berbeco, JT Booth… - Medical …, 2021 - Wiley Online Library
The era of real‐time radiotherapy is upon us. Robotic and gimbaled linac tracking are
clinically established technologies with the clinical realization of couch tracking in …

[HTML][HTML] A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: a multi-institutional study encompassing robotic, gimbaled, multileaf collimator …

E Colvill, J Booth, S Nill, M Fast, J Bedford… - Radiotherapy and …, 2016 - Elsevier
Purpose A study of real-time adaptive radiotherapy systems was performed to test the
hypothesis that, across delivery systems and institutions, the dosimetric accuracy is …

Image-guided radiotherapy and motion management in lung cancer

SS Korreman - The British journal of radiology, 2015 - academic.oup.com
In this review, image guidance and motion management in radiotherapy for lung cancer is
discussed. Motion characteristics of lung tumours and image guidance techniques to obtain …

[HTML][HTML] Clinical implementations of 4D pencil beam scanned particle therapy: report on the 4D treatment planning workshop 2016 and 2017

P Trnková, B Knäusl, O Actis, C Bert, AK Biegun… - Physica Medica, 2018 - Elsevier
Abstract In 2016 and 2017, the 8th and 9th 4D treatment planning workshop took place in
Groningen (the Netherlands) and Vienna (Austria), respectively. This annual workshop …

Two new DOSXYZnrc sources for 4D Monte Carlo simulations of continuously variable beam configurations, with applications to RapidArc, VMAT, TomoTherapy and …

J Lobo, IA Popescu - Physics in Medicine & Biology, 2010 - iopscience.iop.org
We present two new Monte Carlo sources for the DOSXYZnrc code, which can be used to
compute dose distributions due to continuously variable beam configurations. These …

Magnitude, impact, and management of respiration-induced target motion in radiotherapy treatment: a comprehensive review

SA Yoganathan, KJM Das, A Agarwal… - Journal of medical …, 2017 - journals.lww.com
Tumors in thoracic and upper abdomen regions such as lungs, liver, pancreas, esophagus,
and breast move due to respiration. Respiration-induced motion introduces uncertainties in …

Toward a better understanding of the gamma index: Investigation of parameters with a surface‐based distance method a

H Li, L Dong, L Zhang, JN Yang, MT Gillin… - Medical …, 2011 - Wiley Online Library
Purpose: The purpose of this work was to clarify the interactions between the parameters
used in the γ index with the surface‐based distance method, which itself can be viewed as a …

Microdosimetric calculations of the direct DNA damage induced by low energy electrons using the Geant4-DNA Monte Carlo code

S Margis, M Magouni, I Kyriakou… - Physics in Medicine …, 2020 - iopscience.iop.org
To calculate the yield of direct DNA damage induced by low energy electrons using Monte
Carlo generated microdosimetric spectra at the nanometer scale and examine the influence …