A low-power low-noise amplifier with high CMRR for wearable healthcare applications

K Sharma, S Singh, A Sachdeva - AEU-International Journal of Electronics …, 2024 - Elsevier
Low-noise and low-power operation are important parameters of amplifier intended for
wearable healthcare applications. However, along with these parameters the amplifier must …

A review of automatic detection of epilepsy based on EEG signals

Q Ren, X Sun, X Fu, S Zhang, Y Yuan… - Journal of …, 2023 - iopscience.iop.org
Epilepsy is a common neurological disorder that occurs at all ages. Epilepsy not only brings
physical pain to patients, but also brings a huge burden to the lives of patients and their …

A fully differential capacitively-coupled high CMRR low-power chopper amplifier for EEG dry electrodes

E Habibzadeh Tonekabony Shad, M Molinas… - … Integrated Circuits and …, 2020 - Springer
The use of dry electrodes is increasing rapidly. Since their impedance is high, there is a high
impedance node at the connecting node between the electrode and amplifier. This leads to …

[HTML][HTML] Zero-drift operational amplifiers

AA Assim, EV Balashov - Информатика, телекоммуникации и …, 2021 - cyberleninka.ru
This article considers the design and implementation of four different zero-drift operational
amplifiers with 50 nm technology CMOS and compares their characteristics. The aim is …

A 100-V battery charger voltage extender IC with 97% efficiency at 4-A and±0.5% voltage accuracy

BL Hunter, WE Matthews - … on Circuits and Systems I: Regular …, 2020 - ieeexplore.ieee.org
This paper presents an IC that extends the voltage capability of a low voltage battery charger
to 100V for accurately and reliably charging lithium ion (Li-Ion) battery stacks of up to 18 …

Implementation of a Low power Instrumentation Amplifier for Bio-Medical Applications

P Bikki, K Alekhya, K Manjusha… - … on Innovations in …, 2024 - ieeexplore.ieee.org
In biomedical applications, the accurate detection and amplification of physiological signals,
such as ECGs, EEGs, and EMGs, are critical for reliable diagnostics and patient monitoring …

A 5.3 nv/rt Hz, 0.1 nA Input Bias Current Amplifier with both Low and High Voltage Output Capability, Range of 4-50V, Using a BJT Input Stage with a Novel Base …

P Li, Q Wei, B Zhou, L Luo - 2022 IEEE 4th International …, 2022 - ieeexplore.ieee.org
This paper presents a low-noise low-input base current amplifier with both low-voltage and
high voltage output capability. The amplifier has low frequency noise and input base current …

[PDF][PDF] Implementation of Instrumentation Amplifier Design for Biomedical Engineering Applications

TN Wah, HMT Swe, HM Tun - Solid State Technology, 2021 - researchgate.net
The paper emphasizes the implementation of instrumentation amplifier design for
biomedical engineering applications. This study's research problem is how to detect the …

An Ultra-Low Power (86 nW) Low-Voltage (0.6 V) Self-Biased Instrumentation Amplifier for Bio-Medical Applications

K Mukherjee, S Pandit, RK Pal - 2022 IEEE International …, 2022 - ieeexplore.ieee.org
In this article, an operational transconductance amplifier (OTA)-based self-biased, ultra-low
power instrumentation amplifier is proposed. The design is performed in SCL 0.18 μm …

Design of Instrumentation Amplifier and Buffer for Biomedical Applications Using 180 nm Technology

V Pardhi, PP Bansod, DK Mishra, R Jarwal - Proceeding of Fifth …, 2021 - Springer
This paper presents a high-performance Op-Amp based CMOS Instrumentation Amplifier
(IA) and a Buffer for biomedical signal applications. This Instrumentation Amplifier is …