Long-term assessment of the periodontal health of removable partial denture wearers: A systematic review and meta-analysis

LB Drummond, AP Bezerra, A Feldmann… - The Journal of prosthetic …, 2024 - Elsevier
Statement of problem The long-term effects of wearing removable partial dentures (RPDs)
remain unclear. Purpose This systematic review addressed the question “Is the long-term …

Implant-assisted removable partial dentures: Part I. a scoping review of clinical applications

S Kuroshima, Y Ohta, Y Uto, FA Al-Omari… - Journal of …, 2023 - jstage.jst.go.jp
Purpose: This scoping review aimed to systematically map research regarding implant-
assisted removable partial dentures (IARPDs), and identify existing gaps in knowledge …

Performance of graphene-based and polyether-ether-ketone polymers as removable partial denture esthetic clasp materials after cyclic fatigue

MO Hussein - Polymers, 2022 - mdpi.com
The esthetic clasp material is a clinical demand for a satisfactory removable partial denture.
The purpose of this study is to assess the mechanical performance of graphene-based …

Clinical finite element analysis of mandibular displacement model treated with Twin-block appliance

Y Zhang, X Zheng, Q Zhang, Z He, W Huang… - American Journal of …, 2023 - Elsevier
Introduction The mechanical distribution of the mandible is an important factor that affects
functional orthosis during Twin-block (TB) appliance correction. Changes in the mandible …

Mini-implants retaining removable partial dentures in subjects without posterior teeth: A 5-year prospective study comparing the maxilla and the mandible

A Celebic, I Kovacic, N Petricevic, D Puljic, A Popovac… - Medicina, 2023 - mdpi.com
Background and objectives: Long-term studies of clinical outcomes of mini-implants (MDIs)
in the first premolar/canine sites retaining a bilateral free-ending removable partial dentures …

Biomechanical stress in obturator prostheses: a systematic review of finite element studies

MA Mousa, JY Abdullah, NB Jamayet… - BioMed research …, 2021 - Wiley Online Library
Aim. This systematic review is aimed at investigating the biomechanical stress that develops
in the maxillofacial prostheses (MFP) and supporting structures and methods to optimize it …

A narrative review of recent finite element studies reporting references for elastic properties of zirconia dental ceramics

LA Abu-Naba'a - Ceramics, 2023 - mdpi.com
For fixed dentures, new generations of zirconia with diverse characteristics and design
choices are of significant interest. Although in vitro studies and finite element analysis (FEA) …

Evaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis

H Lyu, N Murakami, T Yamazaki, J Wada… - Journal of …, 2023 - jstage.jst.go.jp
Purpose We aimed to assess removable partial denture occlusal rests composed of
polyether-ether-ketone (PEEK) and zirconia, using finite element analysis. Methods Three …

Orofacial esthetics, chewing function, and oral health-related quality of life in Kennedy class I patients with mini-implant-retained removable partial dentures: A 3-year …

V Disha, A Čelebić, S Peršić, M Papić… - Clinical Oral …, 2024 - Springer
This prospective clinical study aimed to assess self-reported orofacial esthetics, chewing
function, and oral health-related quality of life (OHRQoL) over three years in the Kennedy …

Evaluation of the biomechanics of Aramany class I obturators of different designs using numerical and experimental methods. Part I: Retention and associated stress

MA Mousa, A Husein, MI El-Anwar, N Yusoff… - The Journal of prosthetic …, 2024 - Elsevier
Statement of problem Studies on the biomechanics of obturators in the currently used
designs of Aramany class I defect are lacking. Also, modifications of the designs presently …