Pollution flashover voltage of transmission line insulators: Systematic review of experimental works

AA Salem, KY Lau, W Rahiman, Z Abdul-Malek… - IEEE …, 2022 - ieeexplore.ieee.org
Over the past decades, extensive experimental-based research works have been carried out
to investigate the flashover phenomenon on the performance of polluted transmission line …

[图书][B] High-voltage test and measuring techniques

W Hauschild, E Lemke - 2014 - Springer
High-voltage (HV) test and measuring techniques are considered in most general HV text
books (eg Kuechler 2009; Kuffel et al. 2007; Beyer et al. 1986; Mosch et al. 1988; Schufft et …

AC flashover dynamic model suggestion and insulation level selection under fan-shaped pollution

M Ghayedi, R Shariatinasab, M Mirzaie - International Journal of Electrical …, 2022 - Elsevier
The geometry of fan-shaped pollution on the surface of an insulator accounts for two
different values of Salt Deposit Density (SDD), conductivity, and resistance on the leeward …

Improved flashover mathematical model of polluted insulators: A dynamic analysis of the electric arc parameters

MF Palangar, M Mirzaie, A Mahmoudi - Electric Power Systems Research, 2020 - Elsevier
This paper presents an improved dynamic mathematical model of critical parameters for
ceramic insulators based on an extended equivalent electric circuit model of a polluted …

Effects of the inhomogeneous microstructures on buffer layer ablation failure in high voltage cables

H Zhang, J Gao, K Wu, G Zhao, H Sui, K Zhang… - Engineering Failure …, 2023 - Elsevier
In recent years, growing attention has been paid to the buffer layer ablation failure in high
voltage cables. The buffer layer was always regarded as a homogeneous material in …

DC inclined-plane tracking and erosion test of insulating materials

EA Cherney, RS Gorur, A Krivda… - … on Dielectrics and …, 2015 - ieeexplore.ieee.org
The paper reviews previous work on the DC inclined plane test and suggests equivalent DC
voltage levels in parallel to AC voltage in the ASTM inclined plane tracking and erosion test …

Monitoring of dry bands and discharge activities at the surface of textured insulators with AC clean fog test conditions

MEA Slama, M Albano, AM Haddad, RT Waters… - Energies, 2021 - mdpi.com
The aim of this study is the presentation of the results of an in-lab comparative study of
electrical and thermal monitoring of artificially polluted, HTV-textured silicone rubber …

Pollution flashover characteristics of high-voltage outdoor insulators: Analytical study

AA Salem, R Abd Rahman, S Al-Ameri - Arabian Journal for Science and …, 2022 - Springer
This paper introduces an analytical model of contaminated insulators under critical
conditions. The dynamic mathematical model based on the description of the equivalent …

Dynamic modeling of flashover of polymer insulators under polluted conditions based on HGA-PSO algorithm

N Fahimi, HR Sezavar, AAS Akmal - Electric Power Systems Research, 2022 - Elsevier
This paper investigates the pre-flashover conditions of polymer insulators under polluted
condition. This investigation is done by combination of analytical mathematical formulations …

Diagnosis of porcelain and glass insulators conditions using phase angle index based on experimental tests

MF Palangar, M Mirzaie - IEEE Transactions on Dielectrics and …, 2016 - ieeexplore.ieee.org
In this paper, an improved method to diagnose the critical conditions in the porcelain and
glass insulators has been proposed through investigating leakage current (LC) and applied …