[HTML][HTML] A new index for the assessment of power system strength considering reactive power injection and interaction of inverter based resources

L Liyanarachchi, N Hosseinzadeh, A Gargoom… - Sustainable Energy …, 2023 - Elsevier
Power system strength evaluation is vital to maintain secure operation in power systems
having huge dependence on Inverter Based Resources. This paper reviews the state-of-the …

Analytical model of inverter-interfaced renewable energy sources for power system protection

Q Liu, K Jia, B Yang, L Zheng… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The accurate analytical fault analysis model of the emerging inverter-interfaced renewable
energy sources (IIRESs) is an important basis for protection of power system with RESs …

Short-circuit model for type-IV wind turbine generators with decoupled sequence control

T Kauffmann, U Karaagac, I Kocar… - … on Power Delivery, 2019 - ieeexplore.ieee.org
The power system planning and protection studies are becoming more challenging due to
the rapid increase in penetration levels of converter-interfaced renewables. Type-IV wind …

Fault current analysis of type-3 WTs considering sequential switching of internal control and protection circuits in multi time scales during LVRT

Y Chang, J Hu, W Tang, G Song - IEEE Transactions on Power …, 2018 - ieeexplore.ieee.org
As Type-3 wind turbine (WT) has already become a typical type of highly penetrated power
sources in modern power systems, characterizing its properties during grid fault is a basic …

Mechanism analysis of DFIG-based wind turbine's fault current during LVRT with equivalent inductances

Y Chang, J Hu, X Yuan - … of Emerging and Selected Topics in …, 2019 - ieeexplore.ieee.org
Doubly fed induction generator (DFIG)-based wind turbine (WT) has a distinct fault current
contribution that is critical for the power system analysis. This article analyzes the …

Fault analysis of inverter-interfaced RESs considering decoupled sequence control

Q Liu, K Jia, B Yang, L Zheng… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
To adapt to the operation under asymmetric conditions, an increasing number of grid-
following inverter-interfaced renewable energy sources (IIRESs) start to employ the …

Concerning short-circuit current contribution challenges of large-scale full-converter based wind power plants

GMG Guerreiro, R Sharma, F Martin, P Ghimire… - IEEE …, 2023 - ieeexplore.ieee.org
The calculation of short-circuit current contributions from full-converter based type IV wind
turbines and other inverter-based power plants are often simplified. They are represented as …

Generalized Δ-circuit concept for integration of distributed generators in online short-circuit calculations

L Strezoski, M Prica, KA Loparo - IEEE Transactions on Power …, 2016 - ieeexplore.ieee.org
In this paper, a novel concept of Generalized Δ-circuit is proposed, that enables integration
of distributed generators (DGs) based on contemporary technologies into the short-circuit …

An accurate type III wind turbine generator short circuit model for protection applications

T Kauffmann, U Karaagac, I Kocar… - … on Power Delivery, 2016 - ieeexplore.ieee.org
The integration of renewables into power systems introduces several technical challenges
including the development of appropriate models for system protection studies and accurate …

Wind power plant model validation using synchrophasor measurements at the point of interconnection

Y Zhang, E Muljadi, D Kosterev… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
A wind power plant (WPP) is different from a conventional power plant in the sense that a
WPP may consist of hundreds of small (eg, 1.5-MW) wind turbine generators (WTGs) …