A review of techniques for RSS-based radiometric partial discharge localization

DW Upton, KK Mistry, PJ Mather, ZD Zaharis… - Sensors, 2021 - mdpi.com
The lifespan assessment and maintenance planning of high-voltage power systems requires
condition monitoring of all the operational equipment in a specific area. Electrical insulation …

Study of ultra high frequency measurement techniques for online monitoring of partial discharges in high voltage systems

KC Ghanakota, YR Yadam, S Ramanujan… - IEEE Sensors …, 2022 - ieeexplore.ieee.org
Partial Discharge (PD) activity is a pre-cursor for insulation degradation which may
eventually lead to catastrophic failure of the electrical equipment with severe social and …

Effect of sensor position on the measurement of acoustic wave produced by partial discharges

BBF Kongne, GM Mengounou, ET Nkouetcha… - Heliyon, 2024 - cell.com
This paper presents the finite element method (FEM) simulation of the propagation,
measurement and evaluation of the time of arrival (TOA) of the acoustic wave created by a …

Range-Independent TDOA Localization using Stepwise Accuracy Enhancement under Speed Uncertainty

Y Liu, C Chen, Y Wang, C Liu - IEEE Signal Processing Letters, 2023 - ieeexplore.ieee.org
This study proposes a stepwise accuracy enhancement (SAE) method for jointly estimating
signal propagation speed, near-field position, and far-field direction-of-arrival (DOA) without …

Use of optimized centroid and weighted centroid algorithms to locate a partial discharge source by using received signal strength

UF Khan, GMW Janjua, A Ayub, MA Ilyas… - 2020 23rd …, 2020 - ieeexplore.ieee.org
Received signal strength (RSS) based localization of a source is a simple but effective
technique. In RSS based localization source location is estimated by converting obtained …

Medium Voltage Covered Conductors: Advantages, Disadvantages and High Impedance Faults

J Fulneček, O Kabot, M Kunicki… - 2024 24th International …, 2024 - ieeexplore.ieee.org
Covered conductors represent an alternative to classic ACSR for overhead high-voltage
distribution lines. They were first put into operation in the 1970s, especially in the USA and …

Multiple Partial Discharge Sources Detection in Air Insulation Using Antenna Monopole

RF Dewira, IMY Negara, DA Asfani… - 2021 7th International …, 2021 - ieeexplore.ieee.org
Partial Discharge (PD) is an initial phenomenon of a breakdown of isolation equipment. The
continuous failure will damage power equipment lead to a breakdown. Early detection of PD …

An Analysis and Comparison of Partial Discharge Signal Detection and Localization using SDR and radiometric sensor

H Mohamed, U Khan, M Raza, K Abogila… - 2021 29th …, 2021 - ieeexplore.ieee.org
Partial Discharge (PD) is an electrical discharge that occurs within part of the dielectric
between two High Voltage (HV) conductors. PD causes damage to the dielectric which …

A Comparative study on Partial Discharge Emulators

H Mohamed, U Khan, MA Yusuf… - 2020 28th …, 2020 - ieeexplore.ieee.org
Partial Discharge (PD) detection plays a vital role in electrical power stations, it can help
protecting the high voltage equipment, it can prevent explosion of these equipment and …

Otimização Matemática para o Método Radiométrico de Estimação da Localização de Descargas Parciais Baseado em Razão das Potências

JMR de Souza Neto, HD de Macêdo Braz - Simpósio Brasileiro de …, 2020 - sba.org.br
O processo de medição de descargas parciais tem uma longa história como ferramenta de
avaliação de envelhecimento de equipamentos de alta tensão. A localização, porém, ainda …