[图书][B] Power quality: problems and mitigation techniques

B Singh, A Chandra, K Al-Haddad - 2015 - books.google.com
Maintaining a stable level of power quality in the distribution network is a growing challenge
due to increased use of power electronics converters in domestic, commercial and industrial …

Synchronous-reference-frame-based control method for UPQC under unbalanced and distorted load conditions

M Kesler, E Ozdemir - IEEE transactions on industrial …, 2010 - ieeexplore.ieee.org
This paper presents a new synchronous-reference-frame (SRF)-based control method to
compensate power-quality (PQ) problems through a three-phase four-wire unified PQ …

New control of PV solar farm as STATCOM (PV-STATCOM) for increasing grid power transmission limits during night and day

RK Varma, SA Rahman… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
This paper presents a novel concept of utilizing a photovoltaic (PV) solar farm inverter as
STATCOM, called PV-STATCOM, for improving stable power transfer limits of the …

Fuzzy logic controlled shunt active power filter for power quality improvement

SK Jain, P Agrawal, HO Gupta - IEE Proceedings-Electric Power Applications, 2002 - IET
The simulation and experimental study of a fuzzy logic controlled, three-phase shunt active
power filter to improve power quality by compensating harmonics and reactive power …

Power system harmonics research: a survey

GK Singh - European Transactions on Electrical Power, 2009 - Wiley Online Library
The increased use of power electronic controlled equipment, such as variable speed drives,
automated production lines, personal computers and non‐linear electronic devices in power …

TS-fuzzy-controlled active power filter for load compensation

CN Bhende, S Mishra, SK Jain - IEEE transactions on power …, 2006 - ieeexplore.ieee.org
This paper describes the application of Takagi-Sugeno (TS)-type fuzzy logic controller to a
three-phase shunt active power filter for the power-quality improvement and reactive power …

Bacterial foraging technique-based optimized active power filter for load compensation

S Mishra, CN Bhende - IEEE transactions on power delivery, 2006 - ieeexplore.ieee.org
The conventional method of obtaining the coefficients of proportional plus integral (PI)
controllers for the active power filter utilizes a linear model of the PWM inverter. The values …

Experimental investigation of a single-phase UPQC with minimum VA loading

YY Kolhatkar, SP Das - IEEE Transactions on Power Delivery, 2006 - ieeexplore.ieee.org
The paper deals with an optimized unified power-quality conditioner (UPQC), which aims at
the integration of series active and shunt active power filters with minimum volt-ampere (VA) …

Soft computing techniques for the control of an active power filter

P Kumar, A Mahajan - IEEE transactions on power delivery, 2008 - ieeexplore.ieee.org
Nonmodel-based controllers have been explored for the control of a shunt active power filter
(APF) designed for harmonic and reactive current mitigation. In this paper, three soft …

Comparative evaluation of two models of UPQC for suitable interface to enhance power quality

M Basu, SP Das, GK Dubey - Electric Power Systems Research, 2007 - Elsevier
Majority of the dispersed generations from renewable energy sources are connected to the
grid through power electronic interface, which introduce additional harmonics in the …