A conformal TOF–DOI Prism‐PET prototype scanner for high‐resolution quantitative neuroimaging

X Zeng, Z Wang, W Tan, E Petersen, X Cao… - Medical …, 2023 - Wiley Online Library
Background Positron emission tomography (PET) has had a transformative impact on
oncological and neurological applications. However, still much of PET's potential remains …

Innovations in small-animal PET instrumentation

AL Lehnert, RS Miyaoka - PET clinics, 2024 - pet.theclinics.com
There is always a balance to be struck when designing PET systems; overall performance
depends on spatial resolution, detection sensitivity, and timing performance, all of which are …

[HTML][HTML] Recent Breakthroughs in PET-CT Multimodality Imaging: Innovations and Clinical Impact

D Hussain, N Abbas, J Khan - Bioengineering, 2024 - pmc.ncbi.nlm.nih.gov
This review presents a detailed examination of the most recent advancements in positron
emission tomography–computed tomography (PET-CT) multimodal imaging over the past …

High‐resolution and high‐sensitivity PET for quantitative molecular imaging of the monoaminergic nuclei: A GATE simulation study

Z Wang, X Cao, A LaBella, X Zeng, A Biegon… - Medical …, 2022 - Wiley Online Library
Purpose Quantitative in vivo molecular imaging of fine brain structures requires high‐spatial
resolution and high‐sensitivity. Positron emission tomography (PET) is an attractive …

Timing estimation of the exponentiated energy-weighted average for crosshair light sharing TOF-DOI PET detector

E Yoshida, F Obata, T Yamaya - … and Methods in Physics Research Section …, 2024 - Elsevier
In TOF-PET, the method of timestamp calculation is an important factor that affects
coincidence resolving time (CRT). In independent readout detectors, for one-to-one coupled …

A multi-resolution TOF-DOI detector for human brain dedicated PET scanner

W He, Y Zhao, W Huang, X Zhao, M Niu… - Physics in Medicine …, 2024 - iopscience.iop.org
Objective. We propose a single-ended readout, multi-resolution detector design that can
achieve high spatial, depth-of-interaction (DOI), and time-of-flight (TOF) resolutions, as well …

Resolving inter-crystal scatter in a light-sharing depth-encoding PET detector

E Petersen, A LaBella, Y Li, Z Wang… - Physics in Medicine & …, 2024 - iopscience.iop.org
Objective. Inter-crystal scattering (ICS) in light-sharing positron emission tomography (PET)
detectors leads to ambiguity in positioning the initial interaction, which significantly degrades …

Calibration method of crosshair light sharing PET detector with TOF and DOI capabilities

E Yoshida, F Obata, T Yamaya - Biomedical Physics & …, 2023 - iopscience.iop.org
Objective. A crosshair light sharing (CLS) PET detector as a TOF-DOI PET detector with high
spatial resolution has been developed. To extend that work, a detector calibration method …

Effect of depth of interaction resolution on the spatial resolution of SIAT aPET

Z Kuang, L Zhang, N Ren, SM Kinyanjui… - Physics in Medicine …, 2023 - iopscience.iop.org
Objective. Spatial resolution is a crucial parameter for a positron emission tomography (PET)
scanner. The spatial resolution of a high-resolution small animal PET scanner is significantly …

Single-ended readout depth-of-interaction measurements based on random forest algorithm

R Cheng, F Wang, S Li, X Li, Y Liu… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The depth-of-interaction (DOI) information can reduce parallax errors and improve the
spatial resolution of positron emission tomography (PET) imaging. Current DOI detectors …