On flow diversion: the changing landscape of intracerebral aneurysm management

AA Dmytriw, K Phan, JM Moore… - American Journal …, 2019 - Am Soc Neuroradiology
Uptake of flow-diverting technology is rapidly outpacing the availability of clinical evidence.
Most current usage is off-label, and the endovascular community is nearer the beginning …

Overview of different flow diverters and flow dynamics

GA Maragkos, AA Dmytriw, MM Salem, VM Tutino… - …, 2020 - journals.lww.com
Over the past decade, flow diverter technology for endocranial aneurysms has seen rapid
evolution, with the development of new devices quickly outpacing the clinical evidence …

Predictors of cerebral aneurysm persistence and occlusion after flow diversion: a single-institution series of 445 cases with angiographic follow-up

MT Bender, GP Colby, LM Lin, B Jiang… - Journal of …, 2018 - thejns.org
OBJECTIVE Flow diversion requires neointimal stent overgrowth to deliver aneurysm
occlusion. The existing literature on aneurysm occlusion is limited by heterogeneous follow …

Predictive factors of incomplete aneurysm occlusion after endovascular treatment with the pipeline embolization device

GA Maragkos, LC Ascanio, MM Salem… - Journal of …, 2019 - thejns.org
OBJECTIVE The Pipeline embolization device (PED) is a routine choice for the
endovascular treatment of select intracranial aneurysms. Its success is based on the high …

Failure of flow diverter therapy: predictors and management strategies

PA Bonney, M Connor, T Fujii, P Singh, MJ Koch… - …, 2020 - journals.lww.com
Flow diversion is a safe and effective treatment for many types of brain aneurysms. Even so,
there remain some aneurysms that persist despite initial treatment. In studies with the …

Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms

MJ Kole, TR Miller, G Cannarsa, A Wessell… - Journal of …, 2019 - jnis.bmj.com
Objective Flow diversion using the Pipeline embolization device (PED) has become a widely
used treatment method for intracranial aneurysms. However, a subset of aneurysms will fail …

Neck location on the outer convexity is a predictor of incomplete occlusion in treatment with the pipeline embolization device: clinical and angiographic outcomes

T Sunohara, H Imamura, M Goto… - American Journal …, 2021 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: With the increasing use of the Pipeline Embolization
Device for the treatment of aneurysms, predictors of clinical and angiographic outcomes are …

Morphologic feature elongation can predict occlusion status following pipeline embolization of intracranial aneurysms

Y Zhang, C Ma, S Liang, P Yan, F Liang, F Guo… - World neurosurgery, 2018 - Elsevier
Objective To explore whether computed morphologic features can be used as independent
predictors of incomplete occlusion of aneurysms treated with the Pipeline embolization …

Stent-assisted coil embolization versus flow-diverting stent in unruptured vertebral artery dissecting aneurysms: Efficacy and safety comparison

H San Oh, JW Bae, C Hong, KM Kim, DH Yoo… - …, 2023 - journals.lww.com
BACKGROUND: Reconstructive strategies for unruptured vertebral artery dissecting
aneurysms (VADAs) have increasingly relied on newly developed endovascular devices …

Relationship between haemodynamic changes and outcomes of intracranial aneurysms after implantation of the pipeline embolisation device: a single centre study

J Chen, Y Zhang, Z Tian, W Li… - Interventional …, 2019 - journals.sagepub.com
Background Intracranial aneurysms are increasingly being treated by the placement of flow
diverters; however, the factors affecting the outcome of aneurysms treated using flow …