Dose calculation for photon‐emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO

J Perez‐Calatayud, F Ballester, RK Das… - Medical …, 2012 - Wiley Online Library
Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM)
and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for …

EGSnrc Monte Carlo calculated dosimetry parameters for and brachytherapy sources

REP Taylor, DWO Rogers - Medical physics, 2008 - Wiley Online Library
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution
surrounding a high dose rate brachytherapy source and 14 high dose rate and pulsed dose …

Quantifying tumor-selective radiation dose enhancements using gold nanoparticles: a monte carlo simulation study

SX Zhang, J Gao, TA Buchholz, Z Wang… - Biomedical …, 2009 - Springer
Gold nanoparticles can enhance the biological effective dose of radiation delivered to
tumors, but few data exist to quantify this effect. The purpose of this project was to build a …

Update of the CLRP Monte Carlo TG‐43 parameter database for high‐energy brachytherapy sources

H Safigholi, MJP Chamberland, REP Taylor… - Medical …, 2023 - Wiley Online Library
Purpose To update and extend version 2 of the Carleton Laboratory for Radiotherapy
Physics (CLRP) TG‐43 dosimetry database (CLRP_TG43v2) for high‐energy (HE,≥ 50 …

A dosimetric study on the high dose rate Flexisource

D Granero, J Pérez‐Calatayud, E Casal… - Medical …, 2006 - Wiley Online Library
In this work, the dose rate distribution of a new high dose rate source (Flexisource used in
the afterloading Flexitron system, Isodose Control, Veenendaal, The Netherlands) is studied …

The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: a Monte Carlo dose verification study

E Pantelis, P Papagiannis, P Karaiskos… - International Journal of …, 2005 - Elsevier
Purpose: To evaluate the accuracy of clinical dosimetry planning using commercially
available treatment planning systems in 192Ir high-dose-rate (HDR) breast brachytherapy …

Water equivalent phantom materials for 192Ir brachytherapy

AA Schoenfeld, D Harder, B Poppe… - Physics in Medicine & …, 2015 - iopscience.iop.org
Several solid phantom materials have been tested regarding their suitability as water
substitutes for dosimetric measurements in brachytherapy with 192 Ir as a typical high …

Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source

D Granero, J Pérez-Calatayud, F Ballester - Radiotherapy and oncology, 2005 - Elsevier
BACKGROUND AND PURPOSE: High dose rate (HDR) brachytherapy is a highly extended
practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR …

Dosimetry comparison of sources

P Papagiannis, A Angelopoulos, E Pantelis… - Medical …, 2002 - Wiley Online Library
sources besides being widely utilized in the field of conventional brachytherapy also find
use in contemporary peripheral and coronal intravascular applications. In this study, the …

Evaluation of a TG-43 compliant analytical dosimetry model in clinical 192Ir HDR brachytherapy treatment planning and assessment of the significance of source …

E Pantelis, P Papagiannis… - Physics in Medicine …, 2003 - iopscience.iop.org
A simple, time efficient, analytical model incorporating heterogeneities and body dimensions
around a point 192 Ir source is generalized for accurate dosimetry around commercially …